The Dosimetric Effects of Different Beam Energy on Physical Dose Distributions in IMRT Based on Analysis of Physical Indices
- 1 Children’s Cancer Hospital, Cairo, Egypt
- 2 Children’s Cancer Hospital, Cairo, Egypt
- 3 Department of Biophysics, Faculty of Science, Cairo University, Cairo, Egypt
Abstract
This work aimed at evaluating the effect of 6 - and 10-MV photon energies on intensity-modulated radiation therapy (IMRT) treatment plan outcome in different selected diagnostic cases. For such purpose , 19 patients, with different types of non CNS solid tumers, were selected. Clinical step-and-shoot IMRT treatment plans were designed for delivery on a Siemens Oncor accelerator with 82 leafs; multi-leaf collimators (MLCs). To ensure that the similarity or difference among the plans is due to energy alone, the same optimization constraints were applied for both energy plan s . All the parameters like beam angles, number of beams, were kept constant to achieve the same clinical objectives. The Comparative evaluation was based on dose-volumetric analysis of both energy IMRT plans. Both qualitative and quantitative methods were used. Several physical indices for Planning Target Volume (PTV), the relevant Organs at Risk (OARs) as mean dose (Dmean), maximum dose (Dmax), 95% dose (D95), integral dose, total number of segments, and the number of MU were applied. Homogeneity index and conformation number were two other evaluation parameters that were considered in this study. Collectively, the use of 6 MV photons was dosimetrically comparable with 10 MV photons in terms of target coverage, homogeneity, conformity, and OAR savings. While 10-MV plans showed a significant reduction in the number of MUs that varied between 4.2% and 16.6% (P-value = 0.0001) for the different cases compared to 6-MV. The percentage volumes of each patient receiving 2 Gy and 5 Gy were compared for the two energies. The general trend was that 6-MV plans had the highest percentage volume, (P-value = 0.0001, P-value = 0.006) respectively. 10-MV beams actually decreased the integral dose ( from average 183.27 ± 152.38 Gy-Kg to 178.08 ± 147.71 Gy-Kg, P-value = 0.004) compared with 6-MV. In general, comparison of the above parameters showed statistically significant differences between 6-MV and 10-MV groups. Based on the present results, the 10-MV is the optimal energy for IMRT, regardless of the concerns about a potential risk of radiation-induced malignancies. It is recommended that the choice to treat at 10 MV be taken as a risk vs. benefit as the clinical significance remains to be determined on case by case basis.
- M. J. Zelefsky, Y. Yamada, Z. Fuks, et al., “Long-Term Results of Conformal Radiotherapy for Prostate Cancer: Impact of Dose Escalation on Biochemical Tumor Control and Distant Metastases-Free Survival Outcomes,” International Journal of Radiation Oncology, Biology and Physics, Vol. 71, No. 4, 2008, pp. 1028-1033. http://dx.doi.org/10.1016/j.ijrobp.2007.11.066
- J. C. Chow, G. N. Grigorov, R. B. Barnett, “Study on Surface Dose Generated in Prostate Intensity-Modulated Radiation Therapy Treatment,” Medical Dosimetry, Vol. 31, No. 4, 2006, pp. 249-258. http://dx.doi.org/10.1016/j.meddos.2005.07.002
- F. d’Errico, “Dosimetric Issues in Radiation Protection of Radiotherapy Patients,” Mathematics & Physical Sciences, Vol. 118, No. 2, 2006, pp. 205-212. http://dx.doi.org/10.1093/rpd/ncl034
- M. Westermark, J. Arndt, B. Nilsson and A. Brahme, “Comparative Dosimetry in Narrow High-Energy Photon Beams,” Physics in Medicine and Biology, Vol. 45, No. 3, 2000, pp. 685-702. http://dx.doi.org/10.1088/0031-9155/45/3/308
- E. J. Hall, “Intensity-Modulated Radiation Therapy, Protons, and the Risk of Secondary Cancers,” International Journal of Radiation Oncology, Biology and Physics, Vol. 65, No. 1, 2000, pp. 1-7. http://dx.doi.org/10.1016/j.ijrobp.2006.01.027
- S. F. Kry, M. Salehpour, D. S. Followill, et al., “The Calculated Risk of Fatal Secondary Malignancies from Intensity-Modulated Radiation Therapy,” International Journal of Radiation Oncology, Biology and Physics, Vol. 62, No. 4, 2005, pp. 1195-1203. http://dx.doi.org/10.1016/j.ijrobp.2005.03.053
- A. Pirzkall, M. P. Carol, B. Pickett, P. Xia, M. Roach and L. J. Verhey, “The Effect of Beam Energy and Number of Fields on Photon-Based IMRT for Deep-Seated Targets,” International Journal of Radiation Oncology, Biology and Physics, Vol. 53, No. 2, 2002, pp. 434-442. http://dx.doi.org/10.1016/S0360-3016(02)02750-5
- J. Stein, R. Mohan, X. H. Wang, et al., “Number and Orientations of Beams in Intensity-Modulated Radiation Treatments,” Medical Physics, Vol. 24, No. 2, 1997, pp. 149-160. http://dx.doi.org/10. 1118/1.597923
- A. Van’t Riet, A. C. Mak and M. A. Moerland, “A Conformation Number to Quantify the Degree of Conformality in Brachytherapy and External Beam Irradiation: Application to the Prostate,” International Journal of Radiation Oncology, Biology and Physics, Vol. 37, No. 3, 1997, pp. 731-736. http://dx.doi.org/10.1016/S0360-3016(96)00601-3
- H. Aoyama, D. C. Westerley, T. R. Mackie, et al., “Integral Radiation Dose to Normal Structures with Conformal External Beam Radiation,” International Journal of Radiation Oncology, Biology and Physics, Vol. 64, No. 3, 2006, pp. 962-967. http://dx.doi.org/10.1016/j.ijrobp.2005.11.005