Ferromagnetic Dissection in a Rat Glioma Model
- 1 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 2 Department of Neurosurgery, University Hospital Zurich, Zurich, Switzerland
- 3 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 4 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 5 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 6 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 7 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 8 Department of Oncology, The Johns Hopkins University, Baltimore, USA
- 9 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 10 Department of Neurosurgery, The Johns Hopkins University, Baltimore, USA
- 11 Department of Pathology, The Johns Hopkins University, Baltimore, USA
- 12 Department of Ophthalmology, The Johns Hopkins University, Baltimore, USA
- 13 Department of Pediatrics, The Johns Hopkins University, Baltimore, USA
Abstract
Background: We compared cutting and coagulation of a novel ferromagnetic tool (FMwand) with modalities currently used in the clinical setting. Methods: 24 F344 rats with 9L gliosarcoma flank tumours were randomized into 2 groups (n = 12): 1) Five parallel incisions were made into the tumor of each rat using monopolar electrosurgery (MES) cut mode, MES coagulation (coag) mode, FMwand, carbon dioxide (CO 2 ) laser and cold scalpel. 2) Two parallel incisions were made comparing the MES and the FMwand, both with resecting loop tips. The study was then repeated by a second surgeon. The surgeons applied a grading scale (1 = worst, 5 = best) based on their observations. Results: Average scores for FMwand were superior in ease of tissue dissection (3.58), distortion upon tissues (3.67), and smoke production (2.87). CO 2 laser led in effectiveness of hemostasis (4.32). MES cut mode had the highest scores for ease of cleaning of tip (3.17) and speed of dissection (3.92). The FMwand loop device led in all attributes except for ease of cleaning. Conclusions: The FMwand outperformed CO 2 laser significantly in ease and speed. It was superior compared to MES cut mode for hemostasis and superior compared to coag mode in ease and speed, distortion upon tissues and smoke production. The FMwand loop was significantly better compared to MES loop for hemostasis, distortion, ease and speed. The FMwand was shown to be safe and effective for hemostatic soft tissue cutting and coagulation.
- Tudor, K.I., Tudor, M., Buca, A., Cambi-Sapunar, L., Tudor, L., Dujmovic, D., Carija, R., Sucevic, D. and Caric, D. (2008) [Electrosurgery, the Cornerstone of Current Achievements of Brain Tumor Surgery—On the Occasion of 80th Anniversary]. Acta Medica Croatica, 62, 33-40.
- Chehrazi, B. and Collins Jr., W.F. (1981) A Comparison of Effects of Bipolar and Monopolar Electrocoagulation in Brain. Journal of Neurosurgery, 54, 197-203. http://dx.doi.org/10.3171/jns.1981.54.2.0197
- Killory, B.D., Chang, S.W., Wait, S.D. and Spetzler, R.F. (2010) Use of Flexible Hollow-Core CO2 Laser in Microsurgical Resection of CNS Lesions: Early Surgical Experience. Neurosurgery, 66, 1187-1192. http://dx.doi.org/10.1227/01.NEU.0000369195.17553.F3
- Epstein, F. (1983) The Cavitron Ultrasonic Aspirator in Tumor Surgery. Clinical Neurosurgery, 31, 497-505.
- Flamm, E.S., Ransohoff, J., Wuchinich, D. and Broadwin, A. (1978) Preliminary Experience with Ultrasonic Aspiration in Neurosurgery. Neurosurgery, 2, 240-245. http://dx.doi.org/10.1227/00006123-197805000-00010
- Macdonald, J.D., Bowers, C.A., Chin, S.S. and Burns, G. (2014) Comparison of the Effects of Surgical Dissection Devices on the Rabbit Liver. Surgery Today, 44, 1116-1122. http://dx.doi.org/10.1007/s00595-013-0712-4
- Bowers, C.A., Burns, G., Salzman, K.L., Mcgill, L.D. and Macdonald, J.D. (2014) Comparison of Tissue Effects in Rabbit Muscle of Surgical Dissection Devices. International Journal of Surgery, 12, 219-223. http://dx.doi.org/10.1016/j.ijsu.2013.12.014
- Weiss, J.P. and Manwaring, P. (2013) Freedom from Electromagnetic Interference between Cardiac Implantable Electronic Devices and the FMwand Ferromagnetic Surgical System. Journal of Clinical Anesthesia, 25, 681-684. http://dx.doi.org/10.1016/j.jclinane.2013.06.004
- Barth, R.F. and Kaur, B. (2009) Rat Brain Tumor Models in Experimental Neuro-Oncology: The C6, 9L, T9, RG2, F98, BT4C, RT-2 and CNS-1 Gliomas. Journal of Neuro-Oncology, 94, 299-312. http://dx.doi.org/10.1007/s11060-009-9875-7
- Tyler, B., Wadsworth, S., Recinos, V., Mehta, V., Vellimana, A., Li, K., Rosenblatt, J., Do, H., Gallia, G.L., Siu, I.M., Wicks, R.T., Rudek, M.A., Zhao, M. and Brem, H. (2011) Local Delivery of Rapamycin: A Toxicity and Efficacy Study in an Experimental Malignant Glioma Model in Rats. Neuro Oncology, 13, 700-709. http://dx.doi.org/10.1093/neuonc/nor050
- Weizsaecker, M., Deen, D.F., Rosenblum, M.L., Hoshino, T., Gutin, P.H. and Barker, M. (1981) The 9L Rat Brain Tumor: Description and Application of an Animal Model. Journal of Neurology, 224, 183-192. http://dx.doi.org/10.1007/BF00313280