The Impact of Variation in Bladder Volume on the Doses of Target and Organ-at-Risk in Intensity-Modulated Radiation Therapy for Localized Prostate Cancer
- 1 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 2 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 3 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 4 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 5 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 6 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 7 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 8 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 9 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 10 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 11 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 12 Department of Radiation Oncology, Saitama Medical Center, Saitama Medical University, Kawagoe City, Japan
- 13 Department of Radiology, JCHO Tokyo Shinjuku Medical Center, Tokyo, Japan
Abstract
Intensity-modulated radiation therapy (IMRT) has become the mainstay of treatment for localized prostate cancer. In IMRT, minimizing differences between the conditions used during planning CT and daily treatment is important to prevent adverse events in normal tissues. In the present study, we evaluated the impact of variation in bladder volume on the doses to various organs. A total of 35 patients underwent definitive radiotherapy at Saitama Medical Center. A Light Speed RT16 (GE Healthcare) was used for planning and to obtain examination CT images. Such images were acquired after 4 - 6 days of planning CT image acquisition. The IMRT plans were optimized using the planning CT data to satisfy the dose constraints set by our in-house protocols for the PTV and the OARs. The dose distributions were then re-calculated using the same IMRT beams, and checked on examination CT images. It was clear that bladder volume affected the doses to certain organs. We focused on the prostate, bladder, rectum, small bowel, and large bowel. Regression coefficients were calculated for variables that correlated strongly with bladder volume ( p < 0.05). We found that variation in bladder volume [cm 3 ] predicted deviations in the bladder V 70Gy , V 50Gy , and V 30Gy [%]; the maximum dose to the small bowel [cGy]; and the maximum dose to the large bowel [cGy]. The regression coefficients were -0.065, -0.125, -0.180, -10.22, and -9.831, respectively. We evaluated the impacts of such variation on organ doses. These may be helpful when checking a patient’s bladder volume before daily IMRT for localized prostate cancer.
- Pizkall, A., Carol, M., Lohr, F., et al. (2000) Comparison of Intensity-Modulated Radiotherapy with Conventional Conformal Radiotherapy for Complex-Shaped Tumors. International Journal of Radiation Oncology * Biology * Physics, 48, 1371-1380. http://dx.doi.org/10.1016/S0360-3016(00)00772-0
- Emami, B., Lyman, J., Brown, A., et al. (1991) Tolerance of Normal Tissue to Therapeutic Irradiation. International Journal of Radiation Oncology * Biology * Physics, 21, 109-122. http://dx.doi.org/10.1016/0360-3016(91)90171-Y
- Marks, L.B., Carroll, P.R., Dugan, T.C., et al. (1995) The Response of the Urinary Bladder, Urethra, and Ureter to Radiation and Chemotherapy. International Journal of Radiation Oncology * Biology * Physics, 31, 1257-1280. http://dx.doi.org/10.1016/0360-3016(94)00431-J
- De Meerleer, G.O., Villeirs, G.M., Vakaet, L., et al. (2004) The Incidence of Inclusion of the Sigmoid Colon and Small Bowel in the Planning Target Volume in Radiotherapy for Prostate Cancer. Strahlentherapie und Onkologie, 180, 573-581. http://dx.doi.org/10.1007/s00066-004-1267-5
- Brierley, J.D., Cummings, B.J., Wong, C.S., et al. (1994) The Variation of Small Bowel Volume within the Pelvis before and during Adjuvant Radiation for Rectal Cancer. Radiotherapy and Oncology, 31, 110-116. http://dx.doi.org/10.1016/0167-8140(94)90390-5
- Kim, T.H., Chie, E.K., Kim, D.Y., et al. (2005) Comparison of the Belly Board Device Method and the Distended Bladder Method for Reducing Irradiated Small Bowel Volumes in Preoperative Radiotherapy of Rectal Cancer Patients. International Journal of Radiation Oncology * Biology * Physics, 62, 769-775. http://dx.doi.org/10.1016/j.ijrobp.2004.11.015
- Muren, L.P., Smaaland, R. and Dahl, O. (2003) Organ Motion, Set-Up Variation and Treatment Margins in Radical Radiotherapy of Urinary Bladder Cancer. Radiotherapy and Oncology, 69, 291-304. http://dx.doi.org/10.1016/S0167-8140(03)00246-9
- Waldenstrom, A.C., Alsadius, D., Pettersson, N., et al. (2010) Variation in Position and Volume of Organs at Risk in the Small Pelvis. Acta Oncologica, 49, 491-499. http://dx.doi.org/10.3109/02841861003702536
- Stam, M.R., van Lin, E.N., van der Vight, L.P., et al. (2006) Bladder Filling Variation during Radiation Treatment of Prostate Cancer: Can the Use of a Bladder Ultrasound Scanner and Biofeedback Optimize Bladder Filling? International Journal of Radiation Oncology * Biology * Physics, 65, 371-377.
- O’Doherty, U.M., McNair, H.A., Norman, A.R., et al. (2006) Variability of Bladder Filling in Patients Receiving Radical Radiotherapy to the Prostate. Radiotherapy and Oncology, 79, 335-340. http://dx.doi.org/10.1016/j.radonc.2006.05.007