Optimal Thermal Insulation Thickness in Isolated Air-Conditioned Buildings and Economic Analysis
- 1 Department of Mechanical Power Engineering, Faculty of Engineering, Menoufia University, Shebin El Kom, Egypt
Abstract
The removal building heat load and electrical power consumption by air conditioning system are proportional to the outside conditions and solar radiation intensity. Building construction materials has substantial effects on the transmission heat through outer walls, ceiling and glazing windows. Good thermal isolation for buildings is important to reduce the transmitted heat and consumed power. The buildings models are constructed from common materials with 0 - 16 cm of thermal insulation thickness in the outer walls and ceilings, and double-layers glazing windows. The building heat loads were calculated for two types of walls and ceiling with and without thermal insulation. The cooling load temperature difference method, CLTD , was used to estimate the building heat load during a 24-hour each day throughout spring, summer, autumn and winter seasons. The annual cooling degree-day, CDD was used to estimate the optimal thermal insulation thickness and payback period with including the solar radiation effect on the outer walls surfaces. The average saved energy percentage in summer, spring, autumn and winter are 35.5%, 32.8%, 33.2% and 30.7% respectively, and average yearly saved energy is about of 33.5%. The optimal thermal insulation thickness was obtained between 7 - 12 cm and payback period of 20 - 30 month for some Egyptian Cities according to the Latitude and annual degree-days.
- Satman, A. and Yalcinkaya, N. (1999) Heating and Cooling Degree-Hours for Turkey. Energy, 24, 833-840. https://doi.org/10.1016/S0360-5442(99)00035-3
- Durmayaz, A., Kadioglu, M. and Sen, Z. (2000) An Application of the Degree-Hours Method to Estimate the Residential Heating Energy Requirement and Fuel Consumption in Istanbul. Energy, 25, 1245-1256. https://doi.org/10.1016/S0360-5442(00)00040-2
- Buyukalaca, O., Bulut, H. and Yilmaz, T. (2001) Analysis of Variable-Base Heating and Cooling Degree-Days for Turkey. Applied Energy, 69, 269-283. https://doi.org/10.1016/S0306-2619(01)00017-4
- Zedan, M.F. and Mujahid, A.M. (1993) An Efficient Solution for Heat Transfers in Composite Walls with Periodic Ambient Temperature and Solar Radiation. International Journal of Ambient Energy, 4, 83-98. https://doi.org/10.1080/01430750.1993.9675599
- Hasan, A. (1999) Optimizing Insulation Thickness for Buildings Using Life Cycle Cost. Applied Energy, 63, 115-124. https://doi.org/10.1016/S0306-2619(99)00023-9
- Granja, A.D. and Labaki, L.C. (2003) Influence of External Surface Color on the Periodic Heat Flow through a Flat Solid Roof with Variable Thermal Resistance. International Journal of Energy Research, 27, 771-779. https://doi.org/10.1002/er.915
- Mahalia, T.M.I., et al. (2007) Correlation between Thermal Conductivity and the Thickness of Selected Insulation Materials for Building Wall. Energy and Buildings, 39, 182-187. https://doi.org/10.1016/j.enbuild.2006.06.002
- Daouas, N., Hassen, Z. and Ben Aissia, H. (2010) Analytical Periodic Solution for the Study of Thermal Performance and Optimum Insulation Thickness of Building Walls in Tunisia. Applied Thermal Engineering, 30, 319-326. https://doi.org/10.1016/j.applthermaleng.2009.09.009
- Nyers, J. (2014) Economic Optimum of Thermal Insulating Layer for External Wall of Brick. Acta Polytechnica Hungarica, 11, 209-222. https://doi.org/10.12700/APH.11.07.2014.07.13
- Liu, X., et al. (2015) Determination of Optimum Insulation Thickness of Exterior Wall with Moisture Transfer in Hot Summer and Cold Winter Zone of China. Procedia Engineering, 121, 1008-1015. https://doi.org/10.1016/j.proeng.2015.09.072
- Modeste, K.N., et al. (2017) A Comparative Study on Optimum Insulation Thickness of Walls and Energy Savings in Equatorial and Tropical Climate. International Journal of Sustainable Built Environment, 6, 170-182. https://doi.org/10.1016/j.ijsbe.2017.02.001