Research ArticleOpen AccessGoogle Scholar indexed
Measurement of Film Thickness on a Curved Surface by Fiber Optic Probe
Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
- 1 Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
- 2 Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
- 3 Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
- 4 Microgravity Research Centre, Universitè Libre de Bruxelles, Bruxelles, Belgium
Journal of Electronics Cooling and Thermal Control·Volume 03 (2013)·Pages 22–26·Published 29 March 2013·DOI10.4236/jectc.2013.31003
Copy link · social · email
Abstract
A fiber optic sensor is developed in order to measure film thickness along a curved surface. The technique is non-inva sive, which has large bandwidth and good spatial resolution (150 μ m and 300 μ m). A “ finger ” type surface is used on top of which liquid is poured down in a continuing manner. Film thickness is measured with the fiber optic probe on 2 different locations along the “ finger ” surface. Film thickness of 163 and 79 μ m w as measured near the top and in the middle of the fin surface.
KeywordsFiber Optic“Finger” SurfaceCondensation
- R. L. Webb, “Principles of Enhanced Heat Transfer,” John Willey & Sons, Chichester, 1994.
- A. Kraus, A. Aziz and J. Welty, “Extended Surface Heat Transfer,” John Willey & Sons, Chichester, 2001.
- T. A. Shedd and T. A. Newell, “An Automated Optical Liquid Film Thickness Measurement Method, ACRC TR-134,” 1997.
- B. Gholamzadeh and H. Nabovati, “Fiber Optic Sensors,” World Academy of Science, Engineering and Technology, Vol. 42, 2008, pp. 297-307.
- S. Yin, P. B. Ruffin and F. T. S. Yu, “Fiber Optic Sensors,” 2nd Edition, Taylor & Francis Group, London, 2008.
- S. C. M. Yu and C. P. Tso, “Simulation of Fiber Optic Sensors in Determination of Thin Liquid Film Thicknesses,” Advances in Engineering Software, Vol. 22, No. 1, 1995, pp. 55-62. doi:10.1016/0965-9978(95)00007-J
- A. R. Evseev, “Liquid Film Thickness Measurement by Fiber-Optical Probe,” Heat Transfer Research, Vol. 29, No. 6-8, 1998, pp. 535-543.
- S. V. Alekseenko, A. V. Bobylev, A. R. Evseev, V. M. Karsten, D. M. Markovich and B. V. Tarasov, “Measurements of the Liquid-Film Thickness by Fiber-Optic Probe,” Instrument and Experimental Techniques, Vol. 46, No. 2, 2003, pp. 260-264. doi:10.1023/A:1023650623759
- D. V. Zaitsev, D. A. Rodionov and O. A. Kabov, “Study of Thermocapillary Film Rupture Using a Fiber Optical Thickness Probe,” Microgravity Science and Technology, Vol. 19, No. 3-4, 2007, pp. 100-103. doi:10.1007/BF02915765
- D. V. Zaitsev and O. A. Kabov, “Study of the Thermocapillary Effect on a Wavy Falling Film Using a Fiber Optical Thickness Probe,” Experiment in Fluids, Vol. 39, No. 4, 2005, pp. 712-721. doi:10.1007/s00348-005-0003-y
- D. V. Zaitsev, O. A. Kabov and A. R. Evseev, “Measurement of Locally Heated Liquid Film Thickness by a Double-Fiber Optical Probe,” Experiments in Fluids, Vol. 34, 2003, pp. 748-754. doi:10.1007/s00348-003-0621-1
- http://www.mtiinstruments.com/products/fiberopticmeasurement.aspx
- S. J. Kline and F. A. e McClintick, “Describing Uncertanities in Single-Sample Experiments,” Mechanical Engineering, Vol. 75, 1953, pp. 3-8.