Finite Element Analysis and Experimental Characterization of Soil Electrical Resistivity at El Roque de los Muchachos Observatory
- 1 Department of Matter Structure, Thermal and Electronics Physics, Faculty of Physics, University Complutense of Madrid, Madrid, Spain
- 2 Department of Matter Structure, Thermal and Electronics Physics, Faculty of Physics, University Complutense of Madrid, Madrid, Spain
- 3 Department of Matter Structure, Thermal and Electronics Physics, Faculty of Physics, University Complutense of Madrid, Madrid, Spain
- 4 Department of Matter Structure, Thermal and Electronics Physics, Faculty of Physics, University Complutense of Madrid, Madrid, Spain
- 5 Department of Matter Structure, Thermal and Electronics Physics, Faculty of Physics, University Complutense of Madrid, Madrid, Spain
Abstract
This paper presents a study of the soil electrical resistivity of El Roque de los Muchachos Observatory, located in La Palma Island (Spain). This work is mainly motivated by the current plans of building an array of Cherenkov Telescopes (CTA) as well as other scientific installations, which demand low earth resistances for the operation of sensitive instruments, prevention of damage due to electrostatic discharges and protection against lightning strikes. Despite the top quality of the sky, the terrain is mostly filled of hard rocks and materials with high resistivity and hardness. No reliable data of resistivities could be found in available literature, therefore a dedicated resistivity survey onsite like the one presented here is essential to optimize the earth resistance of future installations. In this work, we present measurements done in six different locations of an area covering around 250 m × 275 m and centered on coordinates 28 ˚ 45'42.9"N, 17 ˚ 53'28.5"W. Low resistivity (<2 k Ω m) layers have been found at specific places and depths. The resistivity at the sites has been simulated with COMSOL Multiphysics software using two different models: a simple single layer model and a three-layer model. Agreement with measurements within 10% discrepancies was obtained in all cases. The main contributions of this work are the presentation of reliable values of soil resistivity at ORM, together with the accurate simulation of the soil profiles.
- Acharya, B.S., et al. (2013) Introducing the CTA Concept. Astroparticle Physics, 43, 3-18. https://doi.org/10.1016/j.astropartphys.2013.01.007
- Actis, M., et al. (2011) Design Concepts for the Cherenkov Telescope Array CTA: An Advanced Facility for Ground-Based High-Energy Gamma-Ray Astronomy. Experimental Astronomy, 32, 193-316. https://doi.org/10.1007/s10686-011-9247-0
- Wenner, F. (1916) A Method of Measuring Earth Resistivity. Bulletin of the Bureau of Standards, 12, 469-478. https://doi.org/10.6028/bulletin.282
- Angst, U.M. and Elsener, B. (2014) On the Applicability of the Wenner Method for Resistivity Measurements of Concrete. ACI Materials Journal, 111, 661-672. https://doi.org/10.14359/51686831
- Ruan, W., Southey, R.D., Fortin, S. and Dawalibi, F.P. (2005) Effective Sounding Depths for HVDC Grounding Electrode Design: Wenner versus Schlumberger Methods. 2005 IEEE/PES Transmission Distribution Conference Exposition: Asia and Pacific, Dalian, 1-7.
- Measurement Subcommittee Working Group of the RLC (2012) IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System. https://doi.org/10.1109/IEEESTD.2012.6392181
- Monarque, A., Gastonguay, L., Gagnon, J. and Champagne, G.Y. (1994) New Method for Measuring the Electrical Resistivity of a Thin Layer of Earth. Sixteenth International Telecommunications Energy Conference, Vancouver, 30 October-3 November 1994, 381-384. https://doi.org/10.1109/INTLEC.1994.396640
- Samouelian, A., Cousin, I., Tabbagh, A., Bruand, A. and Richard, G. (2005) Electrical Resistivity Survey in Soil Science: A Review. Soil & Tillage Research, 83, 173-193. https://doi.org/10.1016/j.still.2004.10.004
- Osinowo, O.O. and Falufosi, M.O. (2018) 3D Electrical Resistivity Imaging (ERI) for Subsurface Evaluation in Pre-Engineering Construction Site Investigation. NRIAG Journal of Astronomy and Geophysics, 7, 309-317. https://doi.org/10.1016/j.nrjag.2018.07.001
- Takahashi, T. and Kawase, T. (1990) Analysis of Apparent Resistivity in a Multi-Layer Earth Structure. IEEE Transactions on Power Delivery, 5, 604-612. https://doi.org/10.1109/61.53062
- Zhang, B., Cui, X., Member, S., Li, L., He, J. and Member, S. (2005) Parameter Estimation of Horizontal Multilayer Earth by Complex Image Method. IEEE Transactions on Power Delivery, 20, 1394-1401. https://doi.org/10.1109/TPWRD.2004.834673