A Continuous Electronic Nose Odor Monitoring System in the City of Agadir Morocco
- 1 AQUAMAR Laboratory, Photocatalysis and Environment Team, Department of Chemistry, Faculty of Sciences, University Ibn Zohr, Agadir, Morocco
- 2 AQUAMAR Laboratory, Photocatalysis and Environment Team, Department of Chemistry, Faculty of Sciences, University Ibn Zohr, Agadir, Morocco
- 3 Odotech Inc., Montreal, Canada
Abstract
The city of Agadir is one of the best tourist destinations in Morocco, considered as one of the most beautiful bay in the world, which has a port infrastructure and strong industry based on the processing of seafood which often implicated as the source of odors. In order to identify in real time the sources responsible for the odors experienced in the city center and to act quickly in conjunction with industry, the Wilaya of Souss Massa Draa Region has implemented a continuous odor monitoring and tracking system using electronic noses. The treatment of meteorological data and data sent by electronic nose enables atmospheric dispersion modeling, which allows to follow instantly the odor level in the study area and to identify the sources responsible for odors with receiving warning of incidents odors, data analysis system generated every four minutes allowed to have results confirmed by companions of questionnaires to nearby residents. To reduce odors, recommendations have been suggested, which is to set up affordable and efficient practices.
- Mao, F., Chen, M.-R., Wang, L., Chen, M.-L., Lai, S.-C. and Tsai, C.-J. (2012) Method Development for Determining the Malodor Source and Pollution in Industrial Park. Science of the Total Environment, 437, 270-275. http://dx.doi.org/10.1016/j.scitotenv.2012.08.056
- Gyu Seo, S., Kun Ma, Z., Min Jeon, J., Chul Jung, S. and Bum Lee, W. (2011) Measurements of Key Offensive Odorants in a Fishery Industrial Complex in Korea. Atmospheric Environment, 45, 2929-2936. http://dx.doi.org/10.1016/j.atmosenv.2011.01.032
- Odotech (2001) Caracterisation des emissions atmospheriques et evaluation de l’impact-odeur du lieu d’enfouissement sanitaire de la regie intermunicipale Argenteuil Deux Montagnes (Atmospheric emissions characterization and odor impact assessment of Argenteuil Deux Montagnes landfill area). Odotech Inc., Montreal.
- Nicolas, J., Cors, M., Romain, A.-C. and Delva, J. (2010) Identification of Odour Sources in an Industrial Park from Resident Diaries Statistics. Atmospheric Environment, 44, 1623-1631. http://dx.doi.org/10.1016/j.atmosenv.2010.01.046
- Snidar, R., Culòs, B., Trovarelli, A., Soldati, A., Sironi, S. and Capelli, L. (2008) Evaluation of Odour Emissions from a Landfill through Dynamic Olfactometry, Dispersion Modelling and Electronic Noses. Chemical Engineering Transactions, 15, 315-322.
- EPA (2004) AERMOD: Description of Model Formulation. US Environmental Protection Agency, Research Triangle Park.
- Capelli, L., Sironi, S., Del Rosso, R., Centola, P. and Grande, M.I. (2008) A Comparative and Critical Evaluation of Odour Assessment Methods on a Landfill Site. Atmospheric Environment, 42, 7050-7058.
- Micone, P.G. and Guy, C. (2007) Odour Quantification by a Sensor Array: An Application to Landfill Gas Odours from Two Different Municipal Waste Treatment Works. Sensors and Actuators B, 120, 628-637. http://dx.doi.org/10.1016/j.snb.2006.03.026
- Gorgy, T.G.A. (2003) Validation of an Air Dispersion Model for Odour Impact Assessment. McGill Unversity, Montreal.
- Guo, H., Jacobson, L.D., Schmidt, D.R. and Janni, K.A. (2001) Simulation of Odor Dispersion as Impacted by Weather Conditions. ASAE Publication Number 701P0201, St. Joseph.
- ASTM (2004) ASTM E679-04: Standard Practice for Determination of Odor and Taste Thresholds by a Forced-Choice Ascending Concentration Series Method of Limits. American Society for Testing and Materials, Philadelphia.