Identification of Model Parameters of Vaporized Hydrogen Peroxide Decomposi-tion Flux on Building Materials for Compu-tational Fluid Dynamics — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Identification of Model Parameters of Vaporized Hydrogen Peroxide Decomposi-tion Flux on Building Materials for Compu-tational Fluid Dynamics
Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
,
Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
,
Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
1 Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
2 Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
3 Interdisciplinary Graduate School of Engineering Science, Kyushu University, Fukuoka, Japan
To maintain healthy and sanitary indoor air quality, development of effective decontamination measures for the indoor environment is important and hydrogen peroxide is often used as decontamination agent in healthcare environment. In this study, we focused on the decomposition phenomena of vaporized hydrogen peroxide on wall surfaces in indoor environment and discussed a wall surface decomposition model for vaporized hydrogen peroxide using computational fluid dynamics to simulate the concentration distributions of vaporized hydrogen peroxide. A major drawback to using numerical simulations is the lack of sufficient data on boundary conditions for various types of building materials and hence. We also conducted the fundamental chamber experiment to identify the model parameters of wall surface decomposition model for targeting five types of building materials.
Heckert, R.A., Best, M. and Jordan, L.T. (1997) Efficacy of Vaporized Hydrogen Peroxide against Exotic Animal Viruses. Applied and Environmental Microbiology, 63, 3916-3918.
Klapes, N.A. and Vesley, D. (1990) Vapor-Phase Hydrogen Peroxide as a Surface Decontaminant and Sterilant. Applied and Environmental Microbiology, 56, 503-506.
Johnston, M.D., Lawson, S. and Otter, J.A. (2005) Evaluation of Hydrogen Peroxide Vapour as a Method for the Decontamination of Surfaces Contaminated with Clostridium botulinum Spores. Journal of Microbiological Methods, 60, 403-411. http://dx.doi.org/10.1016/j.mimet.2004.10.021
Murakami, S., Kato, S., Ito, K., Yamamoto, A., Kondo, Y. and Fujimura, J. (2001) Distribution of Chemical Pollutants in a Room Based on CFD Simulation Coupled with Emission/Sorption Analysis. ASHRAE Transactions, 107, 812-820.
Murakami, S., Kato, S., Ito, K. and Zhu, Q. (2003) Modeling and CFD Prediction for Diffusion and Adsorption within Room with Various Adsorption Isotherms. Indoor Air, 13, 20-27. http://dx.doi.org/10.1034/j.1600-0668.13.s.6.3.x
Ataka, Y., Kato, S., Murakami, S., Zhu, Q., Ito, K. and Yokota, T. (2004) Study of Effect of Adsorptive Building Material on Formaldehyde Concentrations: Development of Measuring Methods and Modeling of Adsorption Phenomena. Indoor Air, 14, 51-64. http://dx.doi.org/10.1111/j.1600-0668.2004.00316.x
Ito, K. (2007) Experimental and CFD Analyses Examining Ozone Distribution in 2D Model Room with Laminar and Turbulent Flow Field. Journal of Asian Architecture and Building Engineering, 6, 387-394. http://dx.doi.org/10.3130/jaabe.6.387
Bourdin, D., Mocho, P., Desauziers, V. and Plaisance, H. (2014) Formaldehyde Emission Behavior of Building Materials: On-Site Measurements and Modeling Approach to Predict Indoor Air Pollution. Journal of Hazardous Materials, 280, 164-173. http://dx.doi.org/10.1016/j.jhazmat.2014.07.065
Zhang, Q. and Zhang, G. (2007) Study on TVOCs Concentration Distribution and Evaluation of Inhaled Air Quality under a Re-Circulated Ventilation System. Building and Environment, 42, 1110-1118. http://dx.doi.org/10.1016/j.buildenv.2005.11.012
Ito, K. (2008) Numerical and Experimental Analyses Examining Ozone and Limonene Distributions in Test Chamber with Various Turbulent Flow Fields. International Journal of Air-Conditioning and Refrigeration, 16, 89-99.
Ito, K. and Harashima, H. (2011) Coupled CFD Analysis of Size Distributions on Indoor Secondary Organic Aerosol Derived from Ozone/Limonene Reactions. Building and Environment, 46, 711-718. http://dx.doi.org/10.1016/j.buildenv.2010.10.003
Ito, K., Yagi, H. and Nishikawa, K. (2007) Numerical Modeling and Coupled CFD Analysis of Cluster Ions in Indoor Environment. ROOMVENT 2007, Helsinki, 13-15 June 2007, 129.
Sørensen, D.N. and Weschler, C.J. (2002) Modeling-Gas Phase Reactions in Indoor Environments Using Computational Fluid Dynamics. Atmospheric Environment, 36, 9-18. http://dx.doi.org/10.1016/S1352-2310(01)00479-4
Duran, J.E., Mohseni, M. and Taghipour, F. (2010) Modeling of Annular Reactions with Surface Reaction Using Computational Fluid Dynamics (CFD). Chemical Engineering Science, 65, 1201-1211. http://dx.doi.org/10.1016/j.ces.2009.09.075
Chen, X. and Chen, Q. (2010) Comparison of Different Decontaminant Delivery Methods for Sterilizing Unoccupied Commercial Airliner Cabins. Building and Environment, 45, 2027-2034. http://dx.doi.org/10.1016/j.buildenv.2010.01.013
Satterfield, C.N. and Stein, T.W. (1957) Homogeneous Decomposition of Hydrogen Peroxide Vapor. Journal of Physical Chemistry, 61, 537-540. http://dx.doi.org/10.1021/j150551a006
Verce, M.F., Jayaraman, B., Ford, T.D., Fisher, S.E., Gadgil, A.J. and Carlsen, T.M. (2008) Minimizing Decomposition of Vaporized Hydrogen Peroxide for Biological Decontamination of Galvanized Steel Ducting. Environmental Science and Technology, 42, 5765-5771. http://dx.doi.org/10.1021/es702404g
Aipert, S.M., Knappe, D.R.U. and Ducoste, J.J. (2010) Modeling the UV/Hydrogen Peroxide Advanced Oxidation Process Using Computational Fluid Dynamics. Water Research, 44, 1797-1808. http://dx.doi.org/10.1016/j.watres.2009.12.003
Worsnop, D.R., Zahniser, M.S. and Kolb, C.E. (1989) Temperature Dependence of Mass Accommodation of SO2 and H2O2 on Aqueous Surfaces. The Journal of Physical Chemistry, 93, 1159-1172. http://dx.doi.org/10.1021/j100340a027
Kawasaki, K., Masudome, J., Horata, H. and Oteyama, R. (2012) Bio-Decontamination Technology for a Room of Aseptic Processing Area in Pharmaceutical Plant Using Hydrogen Peroxide Vapor. Japan Air Cleaning Association, 49, 37-43. (In Japanese)
Cano-Ruiz, J.A., Kong, D., Balas, R.B. and Nazaroff, W.W. (1993) Removal of Reactive Gases at Indoor Surfaces: Combining Mass Transport and Surface Kinetics. Atmospheric Environment, 27A, 2039-2050. http://dx.doi.org/10.1016/0960-1686(93)90276-5
Ito, K., Sørensen, D.N. and Weschler, C.J. (2005) Measurements of Mass Accommodation Coefficients Using a Flat-Plate Test Chamber. Indoor Air 2005, 10th International Conference on Indoor Air Quality and Climate, Beijing, 4-9 September 2005, 2335-2339.
Abe, K., Kondoh, T. and Nagano, Y. (1994) A New Turbulence Model for Predicting Fluid Flow and Heat Transfer in Separating and Reattaching Flows-I. Flow Field Calculations. International Journal of Heat and Mass Transfer, 37, 139-151. http://dx.doi.org/10.1016/0017-9310(94)90168-6
Ito, K., Inthavong, K., Kurabuchi, T., Ueda, T., Endo, T., Omori, T., Ono, H., Kato, S., Sakai, K., Suwa, Y., Matsumoto, H., Yoshino, H., Zhang, W. and Tu, J. (2015) CFD Benchmark Tests for Indoor Environmental Problems: Part 1 Isothermal/Non-Isothermal Flow in 2D and 3D Room Model. International Journal of Architectural Engineering Technology, 2, 1-22.
Ito, K., Inthavong, K., Kurabuchi, T., Ueda, T., Endo, T., Omori, T., Ono, H., Kato, S., Sakai, K., Suwa, Y., Matsumoto, H., Yoshino, H., Zhang, W. and Tu, J. (2015) CFD Benchmark Tests for Indoor Environmental Problems: Part 2 Cross-Ventilation Airflows and Floor Heating Systems. International Journal of Architectural Engineering Technology, 2, 23-49. http://dx.doi.org/10.15377/2409-9821.2015.02.01.2
Ito, K., Inthavong, K., Kurabuchi, T., Ueda, T., Endo, T., Omori, T., Ono, H., Kato, S., Sakai, K., Suwa, Y., Matsumoto, H., Yoshino, H., Zhang, W. and Tu, J. (2015) CFD Benchmark Tests for Indoor Environmental Problems: Part 3 Numerical Thermal Manikins. International Journal of Architectural Engineering Technology, 2, 50-75. http://dx.doi.org/10.15377/2409-9821.2015.02.01.3
Ito, K., Inthavong, K., Kurabuchi, T., Ueda, T., Endo, T., Omori, T., Ono, H., Kato, S., Sakai, K., Suwa, Y., Matsumoto, H., Yoshino, H., Zhang, W. and Tu, J. (2015) CFD Benchmark Tests for Indoor Environmental Problems: Part 4 Air-Conditioning Airflows, Residential Kitchen Airflows and Fire-Induced Flow. International Journal of Architectural Engineering Technology, 2, 76-102. http://dx.doi.org/10.15377/2409-9821.2015.02.01.4
Sørensen, D.N. and Nielsen, P.V. (2003) Quality Control of Computational Fluid Dynamics in Indoor Environments. Indoor Air, 13, 2-17. http://dx.doi.org/10.1111/j.1600-0668.2003.00170.x
Zhai, Z., Zhang, Z., Zhang, W. and Chen, Q. (2007) Evaluation of Various Turbulence Models in Predicting Air-Flow and Environments by CFD: Part 1-Summary of Prevalent Turbulence Models. HVAC&R Research, 13, 853-870. http://dx.doi.org/10.1080/10789669.2007.10391459
Zhang, Z., Zhang, W., Zhai, Z. and Chen, Q. (2007) Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part-2: Comparison with Experimental Data from Literature. HVAC&R Research, 13, 871-886. http://dx.doi.org/10.1080/10789669.2007.10391460