Complaints on the indoor environment of the residents in recent decades have become a common problem in the Swedish housing. The buildings themselves are said to be the cause of problems, and it is given a vague picture of both the exposure and the effect of the problems. The symptoms that residents and users state are often common in the population such as headache, fatigue, mucosal disorders and skin problems. It must be considered that the air that people routinely inhale contains impurities of various kinds, both in- and outdoors. An important source of contamination indoors is the microorganisms that are pathogenic, so called agents. Examples of infectious agents are viruses, fungi, bacteria and protozoa. The purpose of this project is to examine whether a physical measurement is possible to obtain for identifying a possible threshold level of air pollution in the indoor environment. In this study, carried out through physical measurements, the results show major deficiencies in the Swedish school environment. If we study the emissions in the important health-related size range of particles larger than 5.0 microns, before and after measures, the environmental benefits are clarified since over 90% of contaminants larger than 5.0 microns have been eliminated.
KeywordsHygiene and HealthIndoor Air QualityIndoor HumidityIndoor Temperature
Merritt, A.S. and Emenius, G. (2013) Environmental Health Report (Miljohalsorapport). Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden. (In Swedish)
The Public Health Agency of Sweden. (In Swedish) https://www.folkhalsomyndigheten.se/livsvillkor-levnadsvanor/miljohalsa-ochhalsoskydd /inomhusmiljo-allmanna-lokaler-och-platser/https://www.folkhalsomyndigheten.se/livsvill kor-levnadsvanor/miljohalsa-och-halsoskydd/inomhusmiljo-allmanna-lokaler-och-platser/t illsynsvagledning-miljobalken/
Swedish Work Environment Authority. Sick-Buildings. https://www.av.se/inomhusmiljo/inomhusmiljo-och-halsobesvar/
The Environmental Goals. Annual Follow-Up of Sweden’s Environmental Quality Objectives and Milestones 2016, Report 6707 Sides 267 -268, Mars 2016, The Swedish Environmental Protection Agency.
Environmental Code (Miljobalken), Swedish Code of Statutes 1998:808 (Svensk forfattningssamling 1998:808), Ministry of the Environment and Energy (Miljo-och energidepartementet), Government Offices (Regeringskansliet/Lagrummet.se). (In Swedish) http://www.riksdagen.se/sv/dokument-lagar/dokument/svensk-forfattningssamling/miljobalk- 1998808_sfs-1998-808
The Work Environment Act (Arbetsmiljolagen), Swedish Code of Statutes 1977:1160 (Svensk forfattningssamling 1977:1160), Ministry of Labour (Arbetsmarknadsdeartimentet), (Regering-skansliet/Lagrummet.se). (In Swedish) https://www.riksdagen.se/sv/dokument-lagar/dokument/svensk-forfattningssamling/arbetsmil jolag-19771160_sfs-1977-1160
Ljungqvist, B., Nydahl, R. and Reinmüller, R. (1989) Measurement in Rooms with Increased Purity Requirements (Matteknik i rum med forhojda renhetskrav). Royal Institute of Technology in Stockholm och Kabi Stockholm. (In Swedish)
Lundberg, I. and Johansson, J. (2002) The Amount of Harmful Particles in the Air Must Be Reduced (Mangden skadliga partiklar i luften mAste minska). County Board in Stockholm (Lansstyrelsen), Sweden.
WAlinder, R. and Friis, L. (1999) Medical Investigation of Indoor Related Disorders 5/99 (Medicinsk utredning av inomhusrelaterade besvar). Occupational and Environmental Medicine, Uppsala, Sweden. (In Swedish)
Brauer, C. (2005) The Sick Building Syndrome Revisited. Department of Occupational Medicine, Copenhagen University, Denmark, 2005
Thorn, A. (1999) The Emergence and Preservation of Sick Building Syndrome. Department of Public Health Sciences, Division of Social Medicine, Karolinska Institute.
Stridh, G. (2003) Are We Measuring the Chemistry for Floor Coverings and How We Interpret in This Case, Measurement Results (Skall vi mata kemin under golvbelaggningar och hur tolkar vi I sA fall matresultat)? Inomhusklimat 203, sidor 102-108, A Wellness and Healthcare Center, Orebro University Hospital, Sweden. (In Swedish)
Eriksson, B., Snaar, J. and Warn, B. (1994) Environmental and Quality of Building Repairs (Miljo-och kvalitetsmarkning av byggreparationer). Sides 22-23, Folksams Research Foundation, Stockholm, Sweden. (In Swedish)
Alsmo, T. (1994) A Study with Questionnaires and Particle Measurements (En studie med enkater och partikelmatningar). Division of Construction Management, Royal Institute of Technology, Stockholm, Sweden. (In Swedish)
Alsmo, T. and Holmberg, S. (2007) Sick Buildings or Not: Indoor Air Quality and Health Problems in Schools. Indoor and Built Environment, 16, 548-555.
Alsmo, T. and Holmberg, S. (2010) A Study of Sources of Airborne Pollutants and Poor Hygiene in Schools. Indoor and Built Environment, 19, 298-304.
Alsmo, T. and Alsmo, C. (2013) A Study of Hygiene in Swedish Schools and Pre-Schools-Sources of Air Pollution. Journal of Environmental Protection, 4, 1349-1359.
Alsmo, T. and Alsmo, C. (2014) Ventilation and Relative Humidity in Swedish Buildings. Journal of Environmental Protection, 5, 1022-1036.
Alsmo, T. and Alsmo, C. (2016) A Comparison of Relative Humidity between Two Swedish Buildings with Different Ventilation Solutions. Journal of Environmental Protection, 7, 855-873.
Ramstorp, M. (1999) Purity Technique and Clean Rooms—An Introduction (Renhetsteknik och rena rum—En introduction). Sides 17-18, Bioteknisk Processdesign AB, Malmo, Sweden. (In Swedish)
Ekstand-Tobin, A. (1993) Correlation between Asthma and Indoor Environments (Samband mellan astma och inomhusmiljo). BorAs, Building Research and SP Technical Research Institute of Sweden. (In Swedish)
OSHA (1989) Carbon Dioxide, Comments from the January 19, 1989, Final Rule on Air Contaminants Project Extracted from 54FR2332 et. seq. This Rule Was Remanded by the U.S. Circuit Court of Appeals and the Limits Are Not Currently in Force.
Berglund, B. and Johansson, B. (1996) Health Effects of Volatile Organic Compounds in Indoor Air. Stockholm’s Universities and Karolinska Institute, Stockholm.
Bornehag, C.G. and Stridh, G. (1995) Volatile Organic Compounds (VOC) in Indoor Air in the Swedish Housing (Flyktiga organiska amnen (VOC) i inomhusluften i det svenska bostadsbestAndet). Karlstad University, Orebro University Hospital, Sweden. (In Swedish)
Bornehag, C.G. (2000) Damp Buildings and Health (Fukt i byggnader och halsa). Building Research, Stockholm, Sweden. (In Swedish)
Bornehag, C.G., Sundell, J., Bonini, S., Custovic, A., Malmberg, P., Skerfing, S., Sigsgaard, T. and Verhoeff, A. (2004) Dampness in Buildings as a Risk Factor for Health Effects, EUROEXPO: A Multidisciplinary Review of the Literature (1998-2000) on Dampness and Mite Exposure in Buildings and Health Effects. Indoor Air, 14, 243-257. http://dx.doi.org/10.1111/j.1600-0668.2004.00240.x
MAnsson, L. (1991) High-Tech Invisible Enemy (Hogteknologins osynliga fiende). Corona AB, Malmo, Sweden. (In Swedish)
Sundell, J. and Kjellman, M. (1995) The Air We Breathe Indoors (Luften vi andas inomhus). Public Health Institute (Folkhalsoinstitutet), Sweden. (In Swedish)
Couch, R.B. (1981) Viruses and Indoor Air Pollution. Bulletin of the New York Academy of Medicine, 57, 907-921.
Smith, E.B. (1983) Atmospheric Factors Affecting Transmission of Infections. The Practitioner, 227, 1667-1677.
Hatch, M.T. and Wolochow, H. (1969) Bacterial Survival: Consequences of the Airborne State. In: Dimmick, R.L. and Akers, A.B., Eds., An Introduction to Experimental Aero Biology, John Wiley and Sons, New York.
Anderson, J.D., Dark, E.A. and Pbto, S. (1968) The Effect of Aerosolization upon Survival and Potassium Retention by Various Bacteria. Microbiology, 52, 99-105. http://dx.doi.org/10.1099/00221287-52-1-99
Rosebury, T. (1947) Experimental Airborne Infection. Williams and Wilkins, Baltimore.
Langmuir, A.D. (1980) Changing Concepts of Airborne Infection of Acute Contagious Diseases: A Reconsideration of Classic Epidemiologic Theories. Annals of the New York Academy of Sciences, 353, 35-44. http://dx.doi.org/10.1111/j.1749-6632.1980.tb18903.x
Moffet, H.L. (1980) Clinical Microbiology. J. B. Lippincott, Philadelphia.
Gwaltney, J.M. (1980) Epidemiology of the Common Cold. Annals of the New York Academy of Sciences, 353, 54-60. http://dx.doi.org/10.1111/j.1749-6632.1980.tb18905.x
Harper, G.J. (1961) Airborne Micro-Organisms: Survival Tests with Four Viruses. Epidemiology and Infection, 59, 479-486. http://dx.doi.org/10.1017/S0022172400039176
Schulman, J.L. and Kilbourne, E.D. (1962) Airborne Transmission of Influenza Virus Infection in Mice. Nature, 182, 1129-1130. http://dx.doi.org/10.1038/1951129a0
Korsgaard, J. (1982) Preventive Measures in House-Dust Allergy. American Review of Respiratory Disease, 125, 80-84.
Arlian, L.G., Bernstein, I.L. and Gallagher, J.S. (1982) The Prevalence of House Dust Mites, Dermatophagoides spp, and Associated Environmental Conditions in Homes in Ohio. Journal of Allergy and Clinical Immunology, 69, 527-532. http://dx.doi.org/10.1016/0091-6749(82)90178-6
Murray, A.B. and Zuk, P. (1979) The Seasonal Variation in a Population of House Dust Mites in a North American City. Journal of Allergy and Clinical Immunology, 64, 266-269. http://dx.doi.org/10.1016/0091-6749(79)90142-8
Arlan, L.G., Brandt, R.L. and Bernstein, R. (1978) Occurrence of House Dust Mites, Dermatophagoides spp. during the Heating Season. Journal of Medical Entomology, 15, 35-42. http://dx.doi.org/10.1093/jmedent/15.1.35
English, P.T. (1980) Medical Mycology. Edward Arnold, London.
NAS (National Academy of Sciences) (1981) Indoor Pollutants. National Academy Press, Washington DC.
IEC Beak Consultants Ltd. (1983) Indoor Air Quality, Cambridge Sealed Homes: A Report for Ontario Ministry of Municipal Affairs and Housing. IEC Beak, Mississauga, Ontario, October.
Sheppard, D., Wong, W.S. and Uehora, C.F. (1981) Lower Threshold and Greater Bronchomotor Responsiveness of Asthmatic Subjects to Sulfur Dioxide. American Review of Respiratory Disease, 122, 873-878.
Zeterberg, J.M. (1973) A Review of Respiratory Virology and the Spread of Virulent and Possibly Antigenic Viruses via Air Conditioning Systems. Annals of Allergy, 31, 228-234.
Becker, M. (1996) The National Board of Health and Welfare (Socialstyrelsen). Indoor Environmental Studies at a nursery in VArgArda Municipality (Inomhusmiljoundersokningar vid ett daghem I VArgArda kommun).
Lundh, A.L. (2007) Swedish Work Environment Authority. Solna, Sweden, Diarienummer: CTB 2007/35764.
Haux, F. (2014) The Public Health Agency of Sweden (Folkhalsomyndigheten). Correspondence 2014-02-11.
SWESIAQ, Swedish Chapter of International Society of Indoor Air Quality and Climate. http://www.swesiaq.se/ http://www.swesiaq.se/swesiaq-modellen.aspx
The Public Health Agency of Sweden. https://www.folkhalsomyndigheten.se/publicerat-material/publikationer/Fastighetsagarnas- egenkontroll/
HenAns School, Orust Municipality, Sweden (2012). www.orust.se
Blom, N. (2014) General Advice on Ventilation. The Public Health Agency’s, FoHMFS 2014:18. The Public Health Agency of Statutes, Solna, Sweden. https://www.folkhalsomyndigheten.se/publicerat-material/foreskrifter-och-allmanna-rad/fohmfs- 201418/
Blom, N. (2014) The Public Health Agency of Public Moisture and Microorganisms, FoHMFS 2014:14. The Public Health Agency of Statutes, Solna, Sweden. https://www.folkhalsomyndigheten.se/publicerat-material/foreskrifter-och-allmanna-rad/fohmfs- 201414
Swedish Work Environment Authority, Workplace design, Provisions AFS 2009:2. https://www.av.se/globalassets/filer/publikationer/foreskrifter/arbetsplatsens-utformning-foreskr ifter-afs2009-2.pdf
Boverket, National Board of Housing, Building and Planning (2016). http://www.boverket.se/sv/boende/halsa--inomhusmiljo-i-ditt-boende/luft-och-ventilation-i-bost ader/