Risk Assessment of Mediterranean Sea Waters on Cooling System of Nuclear Power Plant
- 1 Siting & Environmental Department, NRRA, Cairo, Egypt
- 2 Siting & Environmental Department, NRRA, Cairo, Egypt
Abstract
The study evaluated the impacts such as corrosion and scale formation which may result from, using the once-through pass cooling system of a suggested nuclear power at different selected coastal regions of Alexandria coast. (Abu-Qir, Sidi Kerrir, Estern Harbour, El Max and Sidi Abd Elrhaman). The study had used The Langelier Saturation Index (LSI), which is a measure of a solution’s ability to dissolve or deposit calcium carbonate, which is often used as an indicator of the corrosivity of water. Like the Langelier saturation index, the Ryznar stability index (RSI) is also used to predicate the formation of scale and also the tendency for corrosion due to the concentration of calcium carbonate in the selected water system. Both of the two indexes ((LSI) and (RSI)) had been used to evaluate the internal environmental impact which may be occurred when used once-through pass system is as a cooling method of a coastal pressurized water reactor power plant. The study results showed that the calculated LSI and RSI values for selected regions indicated that, there was a low tendency for scale formation and possibility of corrosion at these selected study areas, so using nickel copper alloys in condenser is recommended to prevent any possibility of attack of corrosion besides the using of chemical treatment method of inlet cooling water system.
- Union of Concerned Scientists (2011) Nuclear Power and Water. Fact Sheet, UCS, Washington DC.
- Turnpenny, A.W.H., Coughlan, J., Ng, B., Crews, P., Bamber, R.N. and Rowles, P. (2010) Cooling Water Operation for New Generation of Nuclear Power Stations in the UK. Water Side Drive, Environment Agency, Rio House.
- Bogh, P. and Bhargava, N. (1974) Combined Dr Y/Wet-Cooling Towers: Their Environmental Promise and Their Problems. Report, IAEA-SH-187/44, International Atomic Energy Authority, 45-62.
- Hawkes, J.M. (2004) The Simulation and Study of Conditions Leading to Axial Offset Anomaly in Pressurized Water Reactors. Georgia Institute of Technology Master of Science Thesis, School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA.
- Bott, T.R. (1995) Heat Exchanger Cleaning. Fouling of Heat Exchangers (Chemical Engineering Monographs), 26, 357-407. https://doi.org/10.1016/B978-044482186-7/50017-8
- Abdosalehi, E., Banegad, H. and Zare Abyaneh, H. (2009) Conceptual Consideration Concerning water quality of Gezel-Ozan River in Iran. Thirtheenth International Water Technology Conference (IWTC), Hurghada, 12-15 March 209, 333-342.
- El-Saharty, A.A. (2013) Radioactive Survey of Coastal Water and Sediments across Alexandria and Rashid Coasts. The Egyptian Journal of Aquatic Research, 39, 21-30. https://doi.org/10.1016/j.ejar.2013.02.001
- APHA, AWWA and WPCF (1995) Standard Methods for Examination of Water and Wastewater. Washington DC.
- Water Cycle (1999) Predictive Modeling of Scale, Corrosion, & Inhibitor Dosages French Creek for Cooling Water. Copyright French Creek Software, Inc., Kimberton.