Integrity Assessment of Pipe System in a Full-Scale Membrane Water Treatment Plant
- 1 Daewoo Institute of Construction Technology, Suwon City, Korea
- 2 Daewoo Institute of Construction Technology, Suwon City, Korea
- 3 Daewoo Institute of Construction Technology, Suwon City, Korea
- 4 Daewoo Institute of Construction Technology, Suwon City, Korea
- 5 The Office of Waterworks Seoul Metropolitan Government, Seoul, Korea
- 6 The Office of Waterworks Seoul Metropolitan Government, Seoul, Korea
- 7 Next Engineering & Service, Seoul, Korea
Abstract
The pipe system roles as a main bridge between membrane modules and pumps in membrane water treatment plants. Membrane operation modes generally consist of filtration and backwash processes in a normal mode, a pressure decay test as an integrity test and a chemical circulation through pipe system in a cleaning mode. Thus factors effecting on membrane performance should be sufficiently considered before design and operation. This study evaluated flow analysis for vibration diagnostic and evaluation of the fatigue lifetime in the microfiltration system applied for a drinking water treatment plant. Vibration of main membrane pipelines was measured to identify the source of vibration. Also natural frequency and fluid dynamics was calculated by computational fluid dynamics. It showed that maximum magnitude frequencies were at 12 Hz and 22 Hz, respectively at water and air pipeline during filtration and backwash. Backwash process caused mainly vibration on the backwash water pipe. The calculated frequency from analysis of frequency response and CFD was in a good agreement with the measured frequency. Fatigue analysis showed that pipelines were getting little damage caused by vibration. Fatigue lifetime was predicted more than 15 years under the operation condition of daily filtration, and more than 27 years under the operation condition of a daily backwash mode, resulting in minor damage on the pipe lifetime.
- Varbanets, M.P., Zurbrügg, C., Swartz, C. and Pronk, W. (2009) Decentralized Systems for Potable Water and the Potential of Membrane Technology, Water Research, 43, 245-265. http://dx.doi.org/10.1016/j.watres.2008.10.030
- Ahuja, S. (2013) Comprehensive Water Quality and Purification. Elsevier, Amsterdam, Boston
- US EPA (2003) Membrane Filtration Guidance Manual Proposal.
- Gupta, V.K. (2013) Environmental Water. Elsevier, Amsterdam.
- Gijsbertsen-Abrahamse, A.J., Cornelissen, E.R. and Hofman, J.A.M.H. (2006) Fiber Failure Frequency and Causes of Hollow Fiber Integrity Loss. Desalination, 194, 251-258. http://dx.doi.org/10.1016/j.desal.2005.11.010
- GamalKhedr, M. (1998) A Case Study of RO Plant Failure Due to Membrane Fouling, Analysis and Diagnosis. Desalination, 120, 107-113. http://dx.doi.org/10.1016/S0011-9164(98)00207-0
- Lee, C.H. and Chang, K.H. (2013) Failure Pressure of a Pressurized Girth-Welded Super Duplex Stainlesssteel Pipe in Reverse Osmosis Desalination Plants. Energy, 61, 565-574. http://dx.doi.org/10.1016/j.energy.2013.08.056
- Chaudhuri, S. (2008) Philosophy of Integrity Assessment of Engineering Components. Materials Science and Engineering A, 489, 259-266. http://dx.doi.org/10.1016/j.msea.2007.12.013
- Jo, J.H., Lee, Y.S., Kim, Y.W. and Jin, H.L. (2012) Structural Integrity Evaluation of Large Main Steam Piping by Water Hammering. Journals of Mechanical Science and Technology, 36, 1103-1108.
- Guo, H., Wyart, Y., Perot, J., Nauleau, F. and Moulin, P. (2010) Low-Pressure Membrane Integrity Tests for Drinking Water Treatment: A Review. Water Research, 44, 41-57. http://dx.doi.org/10.1016/j.watres.2009.09.032
- Johnson, W.T. (1997) Automatic Monitoring of Membraneintegrity in Microfiltration Systems. Desalination, 113, 303-307. http://dx.doi.org/10.1016/S0011-9164(97)00146-X
- Johnson, W.T. (1998) Predicting Log Removal Performance of Membrane Systems Using In-Situ Integrity Testing. Filtration & Separation, 1-35, 26-29.
- Adham, S.S., Jacangelo, J.G. and Laine, J.M. (1995) Low-Pressure Membranes: Assessing Integrity. Journal of American Water Works Association, 87, 62-75.
- Randles, N. (1997) Large Scale Operating Experience in Membrane Systems for Water Andwaste Water Reclamation. Desalination, 108, 205-211. http://dx.doi.org/10.1016/S0011-9164(97)00028-3