Effect of Thermal Shrinkage of Extruded Sheet on Mouthguard Thickness: Influence of Model Undercut
- 1 Department of Physiology, The Nippon Dental University School of Life Dentistry at Niigata, Niigata, Japan
- 2 BANDO Dental Clinic, Ishikawa, Japan
Abstract
The effectiveness and safety of the mouthguard are greatly affected by its thickness. The aim of this study was to investigate the effect of thermal shrinkage of the extruded sheet on the mouthguard thickness depending on the amount of undercut of the model. Mouthguard sheet was used a 4.0 mm thick ethylene-vinyl acetate resin manufactured by extrusion molding. The sheets were placed in the vacuum forming machine with the sheet extrusion direction either vertical (condition V) or parallel (condition P) to the model’s centerline. The working models were three hard plaster models trimmed so that the angles of the anterior teeth to the model base were 90?, 100?, and 110? (Models A, B, and C). The sheet was softened until it sagged 15 mm, and then suction was continued for 30 s. Measurement points of the mouthguard were the incisal portion (incisal edge and labial surface) and molar portion (cusp and buccal surface). The differences in the reduction rate of the thickness due to model form and extrusion direction were analyzed using two-way ANOVA and Bonferroni’s multiple comparison tests. Differences in thickness depending on the extrusion direction of the sheet were observed in Models B and C on the labial surface and in all models on the buccal surface, and the thicknesses obtained under condition P were significantly thinner than those obtained under condition V. The thicknesses of the incisal edge and the cusp were not affected by the extrusion direction. The result of this study was suggested that the labial and buccal thickness of the mouthguard was secured by placing the sheet in the extrusion direction vertical to the model’s centerline. Furthermore, it was clarified that the presence of the undercut of the model tends to increase the influence of the extrusion direction of the sheet on the thickness of the mouthguard.
- Bochnig, M.S., Oh, M.J., Nagel, T., Ziegler, F. and Jost-Brinkmann, P.G. (2017) Comparison of the Shock Absorption Capacities of Different Mouthguards. Dental Traumatology, 33, 205-213. https://doi.org/10.1111/edt.12324
- Gawlak, D., Mańka-Malara, K., Mierzwińska-Nastalska, E., Gieleta, R., Kamiński, T. and Luniewska, M. (2017) A Comparison of Impact Force Reduction by Polymer Materials Used for Mouthguard Fabrication. Acta Bioeng Biomech, 19, 89-95.
- Tribst, J.P.M., de Oliveira, D.P.A.M., Borges, A.L.S. and Bottino, M.A. (2018) Influence of Custom-Made and Stock Mouthguard Thickness on Biomechanical Response to a Simulated Impact. Dental Traumatology, 34, 429-437. https://doi.org/10.1111/edt.12432
- Geary, J.L. and Kinirons, M.J. (2008) Post Thermoforming Dimensional Changes of Ethylene Vinyl Acetate Used in Custom-Made Mouthguards for Trauma Prevention: A Pilot Study. Dental Traumatology, 24, 350-355. https://doi.org/10.1111/j.1600-9657.2007.00550.x
- Maeda, M., Takeda, T., Nakajima, K., Shibusawa, M., Kurokawa, K. and Shimada, A. (2008) In Search of Necessary Mouthguard Thickness: Part 1 from the View Point of Shock Absorption Ability. Journal of Prosthodontic Research, 52, 211-219. https://doi.org/10.2186/jjps.52.211
- Takahashi, M. and Bando, Y. (2019) Thermoforming Method to Effectively Maintain Mouthguard Thickness: Effect of Moving the Model Position Just before Vacuum Formation. Dental Traumatology, 35, 121-127. https://doi.org/10.1111/edt.12447
- Takahashi, M. and Koide, K. (2016) Variation in Mouthguard Thickness According to Heating Conditions during Fabrication: Part 2 Sheet Shape and Effect of Thermal Shrinkage. Dental Traumatology, 32, 185-191. https://doi.org/10.1111/edt.12209
- Farrington, T., Coward, T., Onambele-Pearson, G., Taylor, R.L., Earl, P. and Winwood, K. (2016) An Investigation into the Relationship between Thickness Variations and Manufacturing Techniques of Mouthguards. Dental Traumatology, 32, 14-21. https://doi.org/10.1111/edt.12192
- Takeuchi, M. and Togaya, N. (2006) Effectively of Thermoforming Process for Fabricating of Intraoral Apparatus. Sunashobo, Tokyo, 21-26, 33-44, 54-55, 62-67, 81. (in Japanese)
- Farrington, T., Coward, T., Onambele-Pearson, G., Taylor, R.L., Earl, P. and Winwood, K. (2016) The Effect of Model Inclination during Fabrication on Mouthguard Calliper-Measured and CT Scan-Assessed Thickness. Dental Traumatology, 32, 192-200. https://doi.org/10.1111/edt.12213