The electrochemical corrosion behaviour of three Zr-Ag alloys (Zr-1Ag, Zr-3Ag and Zr-5Ag) was investigated. Open circuit potential, linear potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques were employed in aerated artificial saliva (pH = 4.0) at 37°C. Silver alloying additions are found to be effective in enhancing the corrosion resistance of zirconium in artificial saliva environment. In fact, Zr-Ag alloys exhibit higher open circuit potentials, larger breakdown potentials and higher impedance values as compared to cp Zr. This behaviour can be ascribed to the formation of a thicker and more stable passive film with increasing compactness, able to provide better protection against the corrosion attack.
Mehjabeen, A., Song, T., Xu, W., Tang, H.P. and Qian, M. (2018) Zirconium Alloys for Orthopaedic and Dental Applications. Advanced Engineering Materials, 20, Article ID: 1800207. https://doi.org/10.1002/adem.201800207
Yamamoto, A., Honma, R. and Sumita, M. (1998) Cytotoxicity Evaluation of 43 Metal Salts Using Murine Fibroblasts and Osteoblastic Cells. Journal of Biomedical Materials Research, 39, 331-340. https://doi.org/10.1002/(SICI)1097-4636(199802)39:2 3.0.CO;2-E
Olmedo, D.G., et al. (2011) In vivo Comparative Biokinetics and Biocompatibility of Titanium and Zirconium Microparticles. Journal of Biomedical Materials Research Part A, 98, 604-613.
Guglielmotti, M.B., Cabrini, R.L. and Guerrero, C. (1994) A Method for the Quality Control of Osseointegration in Endosseous Implants. Acta odontológica Latinoamericana, 8, 9-14.
Guglielmotti, M.B., Cabrini, R.L. and Renou, S. (1999) A Histomorphometric Study of Tissue Interface by Laminar Implant Test in Rats. The International Journal of Oral & Maxillofacial Implants, 14, 565-570.
Kulokaov, O.B., Doktorov, A.A., D’iakova, S.V., Denisov-Nikol’skii, I.I. and Grotz, K.A. (2005) Experimental Study of Osseointegration of Zirconium and Titanium Dental Implants. Morfologiia, 127, 52-55.
Kohn, D.H. (1998) Metals in Medical Applications. Current Opinion in Solid State and Materials Science, 3, 309-316. https://doi.org/10.1016/S1359-0286(98)80107-1
Patel, A.M. and Spector, M. (1997) Tribological Evaluation of Oxidized Zirconium Using an Articular Cartilage Counterface: A Novel Material for Potential Use in Hemiarthroplasty. Biomaterials, 18, 441-447. https://doi.org/10.1016/S0142-9612(96)00152-4
Chaturvedi, T.P. (2009) An Overview of the Corrosion Aspect of Dental Implants (Titanium and Its Alloys). Indian Journal of Dental Research, 20, 91-98. https://doi.org/10.4103/0970-9290.49068
Green, N.T. (2002) Fracture of Dental Implants: Literature Review and Report of a Case. Implant Dentistry, 11, 137-143. https://doi.org/10.1097/00008505-200204000-00014
Gomez-Florit, M., Xing, R. and Ramis, J.M. (2014) Differential Response of Human Gingival Fibroblasts to Titanium- and Titanium-Zirconium-Modified Surfaces. Journal of Periodontal Research, 49, 425-436.
Fahey, J., Holmes, D. and Yau, T.-L. (1997) Evaluation of Localized Corrosion of Zirconium in Acidic Chloride Solutions. Corrosion, 53, 54-61. https://doi.org/10.5006/1.3280434
Rosalbino, F., Macciò, D., Saccone, A. and Delfino, S. (2012) Stability of the Passive State of Zr–Nb Crystalline Alloys. Materials and Corrosion, 63, 580-585. https://doi.org/10.1002/maco.201006012
Baboian, R. (1995) Corrosion Tests and Standards: Application and Interpretation. ASTM, Philadelphia.
Al-Mayouf, A.M., Al-Swayih, A.A., Al-Mobarak, N.A. and Al-Jabab, A.S. (2004) Corrosion Behavior of a New Titanium Alloy for Dental Implant Applications in Fluoride Media. Materials Chemistry and Physics, 86, 320-329. https://doi.org/10.1016/j.matchemphys.2004.03.019
Zhang, B.B., Wang, B.L., Li, L. and Zheng, Y.F. (2011) Introduction of Antibacterial Function into Biomedical TiNi Shape Memory Alloy by the Addition of Element Ag. Acta Biomaterialia, 7, 2758-2767.
Takahashi, M., Kikuchi, M., Yakada, Y., Okabe, T. and Okuno, O. (2006) Electrochemical Behavior of Cast Ti-Ag Alloys. Dental Materials Journal, 3, 516-523. https://doi.org/10.4012/dmj.25.516
Rosalbino, F., Delsante, S., Borzone, G. and Scavino, G. (2012) Influence of Noble Metals Alloying Additions on the Corrosion Behaviour of Titanium in a Fluoride-Containing Environment. Journal of Materials Science: Materials in Medicine volume, 23, 1129-1137. https://doi.org/10.1007/s10856-012-4591-9
Robert, G.C., O’Brien, W.J. and Powers, J.M. (1992) Dental Materials: Properties and Manipulation. Mosby-Years Book, Missouri.
Zheng, Y.F., Wang, B.F., Wang, J.G., Li, C. and Zhao, L.C. (2006) Optimization of Mechanical Properties, Biocorrosion Properties and Antibacterial Properties of as-Cast Ti–Cu Alloys. Materials Science and Engineering C, 26, 14-19.
Cremasco, A., Osorio, W.R., Freire, C.M.A., Garcia, A. and Caram, R. (2008) Electrochemical Corrosion Behavior of a Ti-35Nb Alloy for Medical Prostheses. Electrochimica Acta, 53, 4867-4874. https://doi.org/10.1016/j.electacta.2008.02.011
Oliveira, N.T.C., Biaggio, S.R., Rocha-Filho, R.C. and Bocchi, N. (2005) Studies on the Stability of Anodic Oxides on Zirconium Biocompatible Alloys. Journal of Biomedical Materials Research, 39, 397-407. https://doi.org/10.1002/jbm.a.30352
Shukla, A.K. and Balasubramaniam, R. (2006) Effect of Surface Treatment on Electrochemical Behavior of CP Ti, Ti–6Al–4V and Ti–13Nb–13Zr Alloys in Simulated Human Body Fluid. Corrosion Science, 48, 1696-1720. https://doi.org/10.1016/j.corsci.2005.06.003
Zhang, B.B., Zheng, Y.F. and Liu, Y. (2009) Optimization of Mechanical Properties, Biocorrosion Properties and Antibacterial Properties of As-Cast Ti–Cu Alloys. Dental Materials, 25, 467-472.
Lavos-Valereto, I.C., Costa, I. and Wolynec, S. (2002) The Electrochemical Behavior of Ti-6Al-7Nb Alloy with and without Plasma-Sprayed Hydroxyapatite Coating in Hank’s Solution. Journal of Biomedical Materials Research, 63, 664-670. https://doi.org/10.1002/jbm.10351
de Assis, S.L., Wolynec, S. and Costa, I. (2006) Corrosion Characterization of Titanium Alloys by Electrochemical Techniques. Electrochimica Acta, 51, 1815-1819. https://doi.org/10.1016/j.electacta.2005.02.121
Rostomov, N., Judge, W. and Jarjoura, G. (2020) Electrochemical Behavior of Alumix 321 PM and AA6061 Alloys in 3.5 wt% NaCl Solution by Electrochemical Impedance Spectroscopy Measurements. Journal of Materials Science and Chemical Engineering, 8, 42-49. https://doi.org/10.4236/msce.2020.810005
Scully, J.R. and Kelly, R.G. (2003) ASM Handbook. vol. 13, ASM International, Materials Park, OH.
Rondelli, G. and Vicentini, B. (2002) Effect of Copper on the Localized Corrosion Resistance of Ni-Ti Shape Memory Alloy. Biomaterials, 23, 639-644. https://doi.org/10.1016/S0142-9612(01)00142-9
Wang, L.-N. and Luo, J.-L. (2012) Electrochemical Behaviour of Anodic Zirconium Oxide Nanotubes in Simulated Body Fluid. Applied Surface Science, 258, 4830-4833. https://doi.org/10.1016/j.apsusc.2012.01.043
Zhou, F.Y., Wang, B.L., Qiu, K.J, Lin, W.J., Li, L., Wang, Y.B., Nie, F.L. and Zheng, Y.F. (2012) Microstructure, Corrosion Behavior and Cytotoxicity of Zr–Nb Alloys for Biomedical Application. Materials Science and Engineering: C, 32, 851-857. https://doi.org/10.1016/j.msec.2012.02.002
Pauportè, T. and Finne, J. (2006) Impedance Spectroscopy Study of Anodic Growth of Thick Zirconium Oxide Films in H2SO4, Na2SO4 and NaOH Solutions. Journal of Applied Electrochemistry, 36, 33-41. https://doi.org/10.1007/s10800-005-9011-0
Gomez Sanchez, A., Schreiner, W., Duffò, G. and Cerè, S. (2011) Surface Characterization of Anodized Zirconium for Biomedical Applications. Applied Surface Science, 257, 6397-6405. https://doi.org/10.1016/j.apsusc.2011.02.005
Mareci, D., Bolat, G., Cailean, A., Santana, J.J., Izquierdo, J. and Souto, R.M. (2014) Effect of Acidic Fluoride Solution on the Corrosion Resistance of ZrTi Alloys for Dental Implant Application. Corrosion Science, 87, 334-343. https://doi.org/10.1016/j.corsci.2014.06.042
Assis, S.L. and Costa I. (2007) Electrochemical Evaluation of Ti-13Nb-13Zr, Ti-6Al-4V and Ti-6Al-7Nb Alloys for Biomedical Application by Long-Term Immersion Tests. Materials and Corrosion, 58, 329-333. https://doi.org/10.1002/maco.200604027
Liao, X., Kong, X., Dong, P. and Chen, K. (2020) Effect of Pre-Aging, Over-Aging and Re-Aging on Exfoliation Corrosion and Electrochemical Corrosion Behavior of Al-Zn-Mg-Cu Alloys. Journal of Materials Science and Chemical Engineering, 8, 81-88. https://doi.org/10.4236/msce.2020.82008
Aziz-Kerzo, M., Conroy, K.G., Fenelon, A.M., Farrel, S.T. and Breslin, C.B. (2001) Electrochemical Studies on the Stability and Corrosion Resistance of Titanium-Based Implant Materials. Biomaterials, 22, 1531-1539. https://doi.org/10.1016/S0142-9612(00)00309-4
Gudic, S., Radosevic, J. and Kliskic, M.K. (2002) Study of Passivation of Al and Al-Sn Alloys in Borate Buffer Solutions Using Electrochemical Impedance Spectroscopy. Electrochimica Acta, 47, 3009-3016. https://doi.org/10.1016/S0013-4686(02)00246-3
Orazem, M. and Tribollet, B. (2007) Electrochemical Impedance Spectroscopy. Wiley, New York. https://doi.org/10.1002/9780470381588
Oskarsson, M., Ahlberg, E. and Petterson, K. (2001) Oxidation of Zircaloy-2 and Zircaloy-4 in Water and Lithiated Water at 360°C. Journal of Nuclear Materials, 295, 97-108. https://doi.org/10.1016/S0022-3115(01)00480-9
Vasquez, G. and Gonzalez, I. (2007) Diffusivity of Anion Vacancies in WO3 Passive Films. Electrochimica Acta, 52, 6771-6777. https://doi.org/10.1016/j.electacta.2007.04.102
Olsson, C.O.A. and Landolt, D. (2003) Anodisation of a Nb–Zr Alloy. Electrochimica Acta, 48, 3999-4011. https://doi.org/10.1016/S0013-4686(03)00540-1
Takada, Y., Nakajima, H., Okuno, O. and Okabe, T. (2001) Released Ions and Microstructures of Dental Cast Experimental Ti-Ag Alloys. Dental Materials Journal, 20, 34-52. https://doi.org/10.4012/dmj.20.34
Blackwood, S., Chua, A.W.C., Seah, K.H.W., Thampuran, R. and Teoh, S.H. (2000) Corrosion Behaviour of Porous Titanium-Graphite Composites Designed for Surgical Implants. Corrosion Science, 42, 481-503. https://doi.org/10.1016/S0010-938X(99)00103-1