VOCs Destruction by Plasma Catalyst Coupling Using AL-KO PURE Air Purifier on Industrial Scale
- 1 Laboratoire de Physique des Plasmas, Ecole Polytechnique, UPMC, Universite Paris Sud 11, CNRS, Palaiseau, France
- 2 Laboratoire de Physique des Plasmas, Ecole Polytechnique, UPMC, Universite Paris Sud 11, CNRS, Palaiseau, France
- 3 R & D Department of AL-KO Therm GmbH, Jettingen-Scheppach, Germany
- 4 Laboratoire de Physique des Plasmas, Ecole Polytechnique, UPMC, Universite Paris Sud 11, CNRS, Palaiseau, France
Abstract
We have investigated in this study the destruction of acetone and toluene with AL-KO PURE air purifier (AL-KO PURE) on industrial scale. In the case of acetone, 100% pollutant abatement is achieved with AL-KO PURE over more than 80 hours (the test duration time) at the high level concentration of 0.5 ppm (1187 μg/m 3 , about 7 times higher than the average living room level). This corresponds to 0.2 μmol/s with a flow rate of 38.42 m 3 /h. The regeneration of a saturated catalytic filter was also tested. When the catalytic filter of AL-KO PURE is fully saturated with acetone, a 100% acetone destruction efficiency can be achieved at 0.46 ppm concentration with 25% fan speed. Moreover the second pollutant, toluene, has been also studied. 100% toluene abatement also is achieved with AL-KO PURE over more than 80 hours (the test duration time) at the high level concentration of 0.2 ppm (811 μg/m3, 0.087 μmol/s with a flow rate of 38.42 m 3 /h). Finally, the availability for the simultaneous removal of both pollutants, acetone and toluene, has been also studied.
- Pitts, B.J.F. and Pitts, J.N. (2000) Chemistry of the Upper and Lower Atmosphere: Theory, Experiments and Applications. Academic Press, New York.
- Spengler, J. and Sexton, K. (1983) Indoor Air Pollution: A Public Health Perspective. Science, 221, 9-17.
- Zhang, Y. and Xu, Y. (2003) Characteristics and Correlations of VOC Emissions from Building Materials. International Journal of Heat and Mass Transfer, 46, 4877-4883. http://dx.doi.org/10.1016/S0017-9310(03)00352-1
- Publications du gouvernement du Canada (2014) Screening Assessment—Acetone. Sepember 2014.
- Wang, B., Lee, S.C. and Ho, K.F. (2007) Characteristics of Carbonyls: Concentrations and Source Strengths for Indoor and Outdoor Residential Microenvironments in China. Atmospheric Environment, 41, 2851-2861. http://dx.doi.org/10.1016/j.atmosenv.2006.11.039
- Van Durme, J., Dewulf, J., Sysmans, W., Leys, C. and Van Langenhove, H. (2007) Abatement and Degradation Pathways of Toluene in Indoor Air by Positive Corona Discharge. Chemosphere, 68, 1821-1829. http://dx.doi.org/10.1016/j.chemosphere.2007.03.053
- Baelum, J., Lundqvist, G.R., M?lhave, L. and Andersen, N.T. (1990) Human Response to Varying Concentrations of Toluene. International Archives of Occupational and En-vironmental Health, 62, 65-71. http://dx.doi.org/10.1007/BF00397850
- Kang, S.-K., Rohlman, D.S., Lee, M.-Y., Lee, H.-S., Chung, S.-Y. and Anger, W.K. (2005) Neurobehavioral Performance in Workers Exposed to Toluene. Environmental Toxicology and Pharmacology, 19, 645-50. http://dx.doi.org/10.1016/j.etap.2004.12.049
- Holzer, F. (2002) Combination of Non-Thermal Plasma and Hete-rogeneous Catalysis for Oxidation of Volatile Organic Compounds Part 1. Accessibility of the Intra-Particle Volume. Applied Catalysis B: Environmental, 38, 163-181. http://dx.doi.org/10.1016/S0926-3373(02)00040-1
- Jia, Z., Vega-Gonzalez, A., Ben Amar, M., Hassouni, K., Tieng, S., Touchard, S., Kanaev, A. and Duten, X. (2013) Acetaldehyde Removal Using a Diphasic Process Coupling a Silver-Based Nano-Structured Catalyst and a Plasma at Atmospheric Pressure. Catalysis Today, 208, 82-89. http://dx.doi.org/10.1016/j.cattod.2012.10.028
- Thevenet, F., Sivachandiran, L., Guaitella, O., Barakat, C. and Rousseau, A. (2014) Plasma-Catalyst Coupling for Volatile Organic Compound Removal and Indoor Air Treatment: A Review. Journal of Physics D: Applied Physics, 47, 224011. http://dx.doi.org/10.1088/0022-3727/47/22/224011