Seismic Response Improvement of Existing Prototype School Buildings Using Water Tanks, Port Said City, Egypt
- 1 Cairo University, Giza, Egypt
- 2 Department of Structural Engineering, Cairo University, Giza, Egypt
- 3 Department of Structural Engineering, Cairo University, Giza, Egypt
Abstract
There is a global trend for seismic response improvement of new buildings to reduce cost and future damage. It is also important to improve existing structures that are designed without consideration of seismic load or using old provisions that cannot meet the new one. The objective of this paper is to draw attention to evaluate existing reinforced concrete school buildings, then to present a proposed methodology to improve the behaviour of such schools with low cost especially in a developing country. The proposed method uses overhead water tanks as a tuned mass damper. A pushover analysis has been performed to evaluate the existing schools and perform a feasibility study to select the best solution to achieve seismic response improvement of the existing structure. Of course, the proposed methodology can be applied easily to other existing structures.
- Egyptian Code for Loads, ECP 201-1993, Prepared by National Housing and Construction Research Centre.
- Egyptian Code for Loads, ECP 201-2012, National Housing and Construction Research Centre.
- Sobaih, M., El-Ramaily, A. and Kebeasy, R. (1992) Seismic Risk Evaluation of Urban Areas in Egypt. International Journal of Earthquake Engineering, 2, 91-119.
- Sobaih, M., et al. (1997) Seismic Risk Evaluation of highway Bridges. 2nd Egyptian Conference in Earthquake Engineering, EGYQUAKE2, Aswan, 1-3 November 1997, 305-325
- Nazif, M. and Sobaih, M. (2012) A Proposed Methodology for Seismic Risk Evaluation of Existing Reinforced School Buildings. HBRC Journal, 8, 204-211.
- CSI.SAP 2000 V-17 (2010) Integrated Finite Element Analysis and Design of Structures Basic Analysis Reference Manual. Berkeley.
- EuroCode 08 (2011) Design of Structures for Earthquake Resistance, Part 1, General Rules, Seismic Actions and Rules for Buildings. The European Union per Regulation 305/2011, Directive 98/34/EC, Directive 2004/18/E.
- Dattatray, B., Patil, G.R. and Maskar, S. (2014) Use of Overhead Water Tank to Reduce Peak Response of the Structure. International Journal of Innovative Technology and Exploring Engineering, 4, 60-64.
- Patil S.S., Javheri S.B. and Konapure C.G. (2012) Effectiveness of Multiple Tuned Mass Dampers. International Journal of Engineering and Innovative Technology (IJEIT), 1, 78-83.
- Bhattacharjee, E., Halder, L. and Sharma, P.R. (2013) An Experimental Study on Tuned Liquid Damper for Mitigation of Structural Response. International Journal of Advanced Structural Engineering. http://link.springer.com/article/10.1186/2008-6695-5-3/fulltext.html
- Mondal, J., Nimmala, H., Abdulla, S. and Tafreshi, R. (2014) Tuned Liquid Damper. The 3rd International Conference on Mechanical Engineering and Mechatronics, Prague, 14-15 August 2014, Paper No. 68.
- Samanta, A. and Banerji, P. (2008) Structural Control Using Modified Tuned Liquid Dampers. The 14th World Conference on Earthquake Engineering, 14WCEE, Beijing, 12-17 October 2008, 1-8.
- Novo, T., Varum, H., Teixeira-Dias, F., Rodrigues, H., Falcao, S.M., Campos, C.A. and Guerreiro, L. (2013) Tuned Liquid Dampers Simulation for Earthquake Response Control of Buildings. The 15th World Conference on Earthquake Engineering, 15WCEE, Lisbon, 24-28 September 2012, Paper No. 5631.