Monitoring and Identification of the Seismically Isolated “Our Lady of Tears” Shrine in Syracuse
- 1 Department of Structures for Engineering and Architecture, Univesity of Napoli “Federico II”, Naples, Italy
- 2 Department of Structures for Engineering and Architecture, Univesity of Napoli “Federico II”, Naples, Italy
Abstract
This paper describes the installation and management of the monitoring system of the “Our Lady of Tears Shrine” in Syracuse, whose dome is an imposing r.c. and prestressed r.c. structure of about 22,000 ton that was seismically isolated by flat sliding devices with hysteretic dampers. The monitoring system, representing an upgrading and improvement of an old system never made working, has some innovative features, because it allows to manage with the same dedicated hardware and software both the slow (thermal variations, relative humidity, wind direction and velocity) and the fast acquisitions (dynamic vibrations by wind and earthquake). The monitoring system was inserted among those structures maintained and controlled by the Seismic Observatory of Structures of the National Department of Civil Protection. Some records of low magnitude earthquakes allowed to validate the correct behaviour of the whole structure, as well as to make a dynamic identification of the complex construction and to calibrate a detailed finite element model of the Sanctuary, thus predicting isolators’ behaviour under design earthquake.
- Kelly, J.M. (2004) Seismic Isolation. In: Bozorgnia, Y. and Bertero, V.V., Eds., Earthquake Engineering, from Engineering Seismology to Performance-Based Engineering, CRC Press, Boca Raton, 976 p. https://doi.org/10.1201/9780203486245.ch11
- Christopoulos, C., Filiatrault, A. and Bertero, V.V. (2006) Principles of Passive Supplemental Damping and Seismic Isolation. IUSS Press, Pavia, 480 p.
- Matsagar, V.A. and Jangid, R.S. (2008) Base Isolation for Seismic Retrofitting of Structures. Practice Periodical on Structural Design and Construction, 13, 175-185. https://doi.org/10.1061/(ASCE)1084-0680(2008)13:4(175)
- Mokha, A.S., Amin, N., Constantinou, M.C. and Zayas, V. (1996) Seismic Isolation Retrofit of Large Historic Building. Journal of Structural Engineering, 122, 298-308. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:3(298)
- Petrini, L., Pinho, R. and Calvi, M.G. (2006) Criteri di progettazione antisismica degli edifici. IUSS Press, Pavia.
- Soong, T.T. and Spencer, B.F. (2002) Supplemental Energy Dissipation: State-of-the-Art and State-of-the-Practice. Engineering Structures, 24, 243-259. https://doi.org/10.1016/S0141-0296(01)00092-X
- Balageas, D. (2010) Structural Health Monitoring. John Wiley & Sons, Hoboken.
- Farrar, C.R. and Worden, K. (2012) Structural Health Monitoring: A Machine Learning Perspective. John Wiley & Sons, Hoboken. https://doi.org/10.1002/9781118443118
- Nicoletti, M., Lamonaca, B.G. and Spina, D. (2005) The Italian Network for Seismic Monitoring of Structures: Design, Present Level of Realisation and Further Development. Proceedings of the Sixth European Conference on Structural Dynamics (EURODYN 2005), Paris, 4-7 September 2005, page.
- AITEC—Associazione Italiana Tecnico Economica Cemento (2006) The Sanctuary of the “Madonna delle Lacrime”. Special Issue on Italian Concrete Structures for the 2nd fib Congress, Naples, May 2006, 350-353.
- Randazzo, F. (2001) The Sanctuary of the “Madonna delle Lacrime” in Syracuse, Italy. The Italian Industry of Cement, No. 5, May 2001, 394-415.
- Presidenza del Consiglio dei Ministri, Ordinanza No. 3274. Primi elementi in materia di criteri generali per la classificazione sismica del territorio nazionale e normative tecniche per le costruzioni in zona sismica, Roma, 20 Marzo 2003.
- Presidenza del Consiglio dei Ministri, Ordinanza No. 3431. Ulteriori modifiche ed integrazioni all’Ordinanza del PCM n. 3274 del 20.03.2003, Roma, 3 Maggio 2005.