Background and Aim: Determination of the etiology of proximal biliary strictures (PBS) still remains a challenge. Even though EUS-FNA is potentially useful, its role in diagnostic evaluation of PBS is still not established due to a lack of sufficient data. We sought to determine the performance characteristics of EUS-FNA in patients with obstructive jaundice (ObJ) and PBS. Patients and Methods: This is a retrospective analysis and included patients with ObJ and PBS with non-diagnostic brush cytology, who underwent EUS-FNA in our university based practice from March 2002 to February 2009. We evaluated the final diagnoses in study patients and the performance characteristics of EUS-FNA for identifying malignant PBS. Final diagnosis was based on surgical pathology or clinical follow-up of at least 12 months. Results: The study included 28 patients (17 male, 11 female) with mean age of 62.4 ± 14.9 years. The strictures ranged from 10 - 70 mm in length. CT scan identified a hilar mass in 9 patients. EUS-FNA identified malignancy in 12 patients. 18 patients were finally diagnosed to have a malignant stricture and 10 patients had a benign stricture. There were 6 false negative diagnoses. The accuracy of EUS-FNA for diagnosis of cholangiocarcinoma was 78.6%, with 66.6% sensitivity, 100% specificity, 62.5% NPV and 100% PPV. Conclusions: EUS-FNA can diagnose malignancy in 66.6% of jaundiced patients with PBS and non-diagnostic brush cytology and may have a role in their further diagnostic evaluation.
DeWitt, J., Misra, V.L., Leblanc, J.K., et al. (2006) EUS-guided FNA of proximal biliary strictures after negative ERCP brush cytology results. Gastrointestinal Endoscopy, 64, 325-333. doi:10.1016/j.gie.2005.11.064
Fritscher-Ravens, A., Broering, D.C., Knoefel, W.T., et al. (2004) EUS-guided fine-needle aspiration of suspected hilar cholangiocarcinoma in potentially operable patients with negative brush cytology. The American Journal of Gastroenterology, 99, 45-51. doi:10.1046/j.1572-0241.2003.04006.x
Fritscher-Ravens, A., Broering, D.C., Sriram, P.V., et al. (2000) EUS-guided fine-needle aspiration cytodiagnosis of hilar cholangiocarcinoma: A case series. Gastrointestinal Endoscopy, 52, 534-540. doi:10.1067/mge.2000.109589
R?sch, T., Hofrichter, K., Frimberger, E., et al. (2004) ERCP or EUS for tissue diagnosis of biliary strictures? A prospective comparative study. Gastrointestinal Endos- copy, 60, 390-396. doi:10.1016/S0016-5107(04)01732-8
Eloubeidi, M.A., Chen, V.K., Jhala, N.C., et al. (2004) Endoscopic ultrasound-guided fine needle aspiration biopsy of suspected cholangiocarcinoma. Clinical Gastroenterology Hepatology, 2, 209-213. doi:10.1016/S1542-3565(04)00005-9
Glasbrenner, B., Ardan, M., Boeck, W., et al. (1999) Prospective evaluation of brush cytology of biliary strictures during endoscopic retrograde cholangiopancreatography. Endoscopy, 31, 712-717. doi:10.1055/s-1999-73
Lin, F. and Staerkel, G. (2003) Cytologic criteria for well differentiated adenocarcinoma of the pancreas in fine-needle aspiration biopsy specimens. Cancer, 99, 44-50. doi:10.1002/cncr.11012
Chahal, P. and Baron, T.H. (2006) Endoscopic palliation of cholangiocarcinoma. Current Opinion in Gastroenterology, 22, 551-560. doi:10.1097/01.mog.0000239872.12081.a4
Simmons, D.T., Baron, T.H., Petersen, B.T., et al. (2006) A novel endoscopic approach to brachytherapy in the management of Hilar cholangiocarcinoma. The American Journal of Gastroenterology, 101, 1792-1796. doi:10.1111/j.1572-0241.2006.00700.x
Malhi, H. and Gores, G.J. (2006) Review article: The modern diagnosis and therapy of cholangiocarcinoma. Alimentary Pharmacology & Therapeutics, 23, 1287-1296. doi:10.1111/j.1365-2036.2006.02900.x
Nagino, M., Kamiya, J., Nishio, H., et al. (2006) Two hundred forty consecutive portal vein embolizations before extended hepatectomy for biliary cancer: Surgical outcome and long-term follow-up. Annals of Surgery, 243, 364-372. doi:10.1097/01.sla.0000201482.11876.14
Arnagin, W.R., Zager, J.S., Hezel, M., et al. (2006) Treatment of cholangiocarcinoma with oncolytic herpes simplex virus combined with external beam radiation therapy. Cancer Gene Therapy, 13, 326-334.
Rea, D.J., Heimbach, J.K., Rosen, C.B., et al. (2005) Liver transplantation with neoadjuvant chemoradiation is more effective than resection for hilar cholangiocarcinoma. Annals of Surgery, 242, 451-458.
Ortner, M.E., Caca, K., Berr, F., et al. (2003) Successful photodynamic therapy for nonresectable cholangiocarcinoma: A randomized prospective study. Gastroenterology, 125, 1355-1363. doi:10.1016/j.gastro.2003.07.015
Mansfield, J.C., Griffin, S.M., Wadehra, V., et al. (1997) A prospective evaluation of cytology from biliary strictures. Gut, 40, 671-677.
Harewood, G.C., Baron, T.H., Stadheim, L.M., et al. (2004) Prospective, blinded assessment of factors influencing the accuracy of biliary cytology interpretation. The American Journal of Gastroenterology, 99, 1464- 1469. doi:10.1111/j.1572-0241.2004.30845.x
De Bellis, M., Fogel, E.L., Sherman, S., et al. (2003) Influence of stricture dilation and repeat brushing on the cancer detection rate of brush cytology in the evaluation of malignant biliary obstruction. Gastrointestinal Endoscopy, 58, 176-182. doi:10.1067/mge.2003.345
Farrell, R.J., Jain, A.K., Brandwein, S.L., et al. (2001) The combination of stricture dilation, endoscopic needle aspiration, and biliary brushings significantly improves diagnostic yield from malignant bile duct strictures. Gastrointestinal Endoscopy, 54, 587-594. doi:10.1067/mge.2001.118715
Venu, R.P., Geenen, J.E., Kini, M., et al. (1990) Endoscopic retrograde brush cytology. A new technique. Gastroenterology, 99, 1475-1479.
Van Heek, N.T., Clayton, S.J., Sturm, P.D., et al. (2005) Comparison of the novel quantitative ARMS assay and an enriched PCR-ASO assay for K-ras mutations with conventional cytology on endobiliary brush cytology from 312 consecutive extrahepatic biliary stenoses. Journal of Clinical Pathology, 58, 1315-1320. doi:10.1136/jcp.2004.022707
Khalid, A., Pal, R., Sasatomi, E., et al. (2004) Use of microsatellite marker loss of heterozygosity in accurate diagnosis of pancreaticobiliary malignancy from brush cytology samples. Gut, 53, 1860-1865. doi:10.1136/gut.2004.039784
Kipp, B.R., Stadheim, L.M., Halling, S.A., et al. (2004) A comparison of routine cytology and fluorescence in situ hybridization for the detection of malignant bile duct strictures. The American Journal of Gastroenterology, 99, 1675-1681. doi:10.1111/j.1572-0241.2004.30281.x
Baron, T.H., Harewood, G.C., Rumalla, A., et al. (2004) A prospective comparison of digital image analysis and routine cytology for the identification of malignancy in biliary tract strictures. Clinical Gastroenterology and Hepatology, 2, 214-219. doi:10.1016/S1542-3565(04)00006-0
Tascilar, M., Sturm, P.D., Caspers, E., et al. (1999) Diagnostic p53 immunostaining of endobiliary brush cytology: preoperative cytology compared with the surgical specimen. Cancer, 87, 306-311. doi:10.1002/(SICI)1097-0142(19991025)87:5 3.0.CO;2-Y
Agarwal, B., Abu-Hamda, E., Molke, K.L., et al. (2004) Endoscopic ultrasound-guided fine needle aspiration and multidetector spiral CT in the diagnosis of pancreatic cancer. The American Journal of Gastroenterology, 99, 844-850. doi:10.1111/j.1572-0241.2004.04177.x
Chang, K.J., Nguyen, P., Erickson, R.A., et al. (1997) The clinical utility of endoscopic ultrasound-guided fine-needle aspiration in the diagnosis and staging of pancreatic carcinoma. Gastrointestinal Endoscopy, 45, 387-393. doi:10.1016/S0016-5107(97)70149-4
Giovannini, M., Seitz, J.F., Monges, G., et al. (1995) Fine-needle aspiration cytology guided by endoscopic ultrasonography: results in 141 patients. Endoscopy, 27, 171-177. doi:10.1055/s-2007-1005657
Wiersema, M.J., Vilmann, P., Giovannini, M., et al. (1997) Endosonography-guided fine-needle aspiration bi- opsy: Diagnostic accuracy and complication assessment. Gastroenterology, 112, 1087-1095. doi:10.1016/S0016-5085(97)70164-1
Faigel, D.O., Ginsberg, G.G., Bentz, J.S., et al. (1997) Endoscopic ultrasound-guided real-time fine-needle aspiration biopsy of the pancreas in cancer patients with pancreatic lesions. Journal of Clinical Oncology, 15, 1439-1443.
Williams, D.B., Sahai, A.V., Aabakken, L., et al. (1999) Endoscopic ultrasound guided fine needle aspiration biopsy: A large single centre experience. Gut, 44, 720-726. doi:10.1136/gut.44.5.720
Fritscher-Ravens, A., Izbicki, J.R., Sriram, P.V., et al. (2000) Endosonography-guided, fine-needle aspiration cytology extending the indication for organ-preserving pancreatic surgery. The American Journal of Gastroenterology, 95, 2255-2260. doi:10.1111/j.1572-0241.2000.02311.x
Tio, T.L. and Tytgat, G.N. (1986) Endoscopic ultrasonography of bile duct malignancy and the preoperative assessment of local resectability. Scandinavian Journal of Gastroenterology, 123, 151-157. doi:10.3109/00365528609091877
Vilmann, P. (1998) Endoscopic ultrasound-guided fineneedle biopsy in Europe. Endoscopy, 30, 161-162. doi:10.1055/s-2007-1001506
Corvera, C.U., Blumgart, L.H., Darvishian, F., et al. (2005) Clinical and pathologic features of proximal biliary strictures masquerading as hilar cholangiocarcinoma. Journal of the American College of Surgeons, 201, 862- 869. doi:10.1016/j.jamcollsurg.2005.07.011
Krishna, N.B., Saripalli, S., Safdar, R., et al. (2007) Intraductal US in evaluation of biliary strictures without a mass lesion on CT scan or magnetic resonance imaging: Significance of focal wall thickening and extrinsic compression at the stricture site. Gastrointestinal Endoscopy, 66, 90-96. doi:10.1016/j.gie.2006.10.020
Tamada, K. and Sugano, K. (2000) Diagnosis and non-surgical treatment of bile duct carcinoma: Developments in the past decade. Journal of Gastroenterology, 35, 319-325. doi:10.1007/s005350050355
Tamada, K., Tomiyama. T., Wada, S., et al. (1999) Detection of bile duct cancer in an early stage by intraductal ultrasonography (in Japanese with English abstract). Endoscopy, 11, 1164-1172.