Radio Frequency Tank Circuit for Probing Planar Lipid Bilayers
- 1 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 2 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 3 Laboratory of Nanodevices and Application, Suzhou Institute of Nanotech and Nanobionics, Chinese Academy of Sciences, Beijing, China
- 4 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 5 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 6 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 7 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 8 Electrical Engineering, Kyungpook National University, Daegu, Republic of Korea;
- 9 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA;
- 10 Laboratory for Molecular-Scale Engineering, Department of Electrical and Computer Engineering, University of Wisconsin-Madi- son, Madison, USA
- 11 Genome Center of Wisconsin, University of Wisconsin-Madison, Madison, USA.
Abstract
We present first results from a hybrid coplanar waveguide microfluidic tank circuit for monitoring lipid bilayer formation and fluctuations of integrated proteins. The coplanar waveguide is a radio frequency resonator operating at ~250 MHz. Changes within the integrated microfluidic chamber, such as vesicle bursting and subsequent nanopore formation alter the reflected signal, and can be detected with nanosecond resolution. We show experimental evidence of such alterations when the microfluidic channel is filled with giant unilamellar vesicles (GUVs). Subsequent settling and bursting of the GUVs form planar lipid bilayers, yielding a detectable change in the resonant frequency of the device. Results from finite element simulations of our device correlate well with our experimental evidence. These simulations also indicate that nanopore formation within the bilayer is easily detectable. The simulated structure allows for incorporation of microfluidics as well as simultaneous RF and DC recordings. The technique holds promise for high throughput drug screening applications and could also be used as an in - plane probe for various other applications. It opens up possibilities of exploring ion channels and other nano scale pores in a whole new frequency band allowing for operating at bandwidths well above the traditional DC methods.
- B. Sakmann and E. Neher, “Single-Channel Recording,” 2nd Edition, Plenum Press, New York, 1995.
- N. Fertig, R. H. Blick and J. C. Behrends, “Whole Cell Patch Clamp Recording Performed on a Planar Glass Chip,” Biophysical Journal, Vol. 82, No. 6, 2002, pp. 3056-3062. http://dx.doi.org/10.1016/S0006-3495(02)75646-4
- S. Ramachandran, D. W. van der Weide and R. Blick, “Direct Microwave Transmission on Single α-Hemolysin Pores,” Applied Physics Letters, Vol. 99, No. 9, 2011, Article ID: 093105. http://dx.doi.org/10.1063/1.3626586
- H. S. Kim, S. Ramachandran, E. Stava, D. W. V. D. Weide and R. H. Blick, “Radio-Frequency Response of Single Pores and Artificial Ion Channels,” New Journal of Physics, Vol. 13, 2011, Article ID: 093033. http://dx.doi.org/10.1088/1367-2630/13/9/093033
- G. R. Facer, D. A. Notterman and L. L. Sohn, “Dielectric Spectroscopy for Bioanalysis: From 40 Hz to 26.5 GHz in a Microfabricated Wave Guide,” Applied Physics Letters, Vol. 78, No. 7, 2001, pp. 996-998. http://dx.doi.org/10.1063/1.1347020
- J. Hefti, A. Pan and A. Kumar, “Sensitive Detection Method of Dielectric Dispersions in Aqueous-Based, Surface-Bound Macromolecular Structures Using Microwave Spectroscopy,” Applied Physics Letters, Vol. 75, No. 12, 1999, pp. 1802-1804. http://dx.doi.org/10.1063/1.124825
- S. Ramachandran, R. Blick and D. van der Weide, “Radio Frequency Rectification on Membrane Bound Pores,” Nanotechnology, Vol. 21, No. 7, 2010, Article ID: 075201. http://dx.doi.org/10.1088/0957-4484/21/7/075201
- R. J. Schoelkopf, P. Wahlgren, A. A. Kozhevnikov, P. Delsing and D. E. Prober, “The Radio-Frequency Single-Electron Transistor (rf-set): A Fast and Ultrasensitive Electrometer,” Science, Vol. 280, No. 5367, 1998, pp. 1238-1242. http://dx.doi.org/10.1126/science.280.5367.1238
- H. Qin and D. A. Williams, “Radio-Frequency Point-Contact Electrometer,” Applied Physics Letters, Vol. 88, No. 20, 2006, Article ID: 203506. http://dx.doi.org/10.1063/1.2205159
- D. K. Wood, M. V. Requa and A. N. Cleland, “Microfabricated High-Throughput Electronic Particle Detector,” Review of Scientific Instruments, Vol. 78, No. 10, 2007, Article ID: 104301. http://dx.doi.org/10.1063/1.2794230
- M. Yu, H. S. Kim and R. H. Blick, “Laser Drilling of Nano-Pores in Sandwiched Thin Glass Membranes,” Optics Express, Vol. 17, No. 12, 2009, pp. 10044-10049. http://dx.doi.org/10.1364/OE.17.010044