Non-Enzymatic Glucose Sensor Based on the Novel Flower Like Morphology of Nickel Oxide
- 1 Division of Physical Electronics and Nanotechnology, Department of Science and Technology, Link?ping University, Campus Norrk?ping, Norrk?ping, Sweden;
- 2 Division of Physical Electronics and Nanotechnology, Department of Science and Technology, Link?ping University, Campus Norrk?ping, Norrk?ping, Sweden;
- 3 Department of Physics, Chemistry, and Biology (IFM), Link?ping University, Link?ping, Sweden.
- 4 Division of Physical Electronics and Nanotechnology, Department of Science and Technology, Link?ping University, Campus Norrk?ping, Norrk?ping, Sweden;
Abstract
In this study, novel nickel oxide (NiO) flowers like nanostructures were fabricated onto gold coated glass substrate by hydrothermal method using high alkaline pH medium. The structural study of nickel oxide nanostructures was performed by scanning electron microscopy (SEM) and X-ray differaction (XRD) techniques. Nickel oxide nanostructures are highly dense, uniform and possess good crystalline quality. The so prepared structures were investigated for their electrochemical properties by cyclic voltammetry and amperometric techniques. The nickel oxide flower like morphology has shown good electrochemical performances for the oxidation of glucose. The presented sensing material was able to detected glucose in a wide range of concentration of 0.001 mM to 8 mM with a high sensitivity (123 μmA/mM) and regression coefficient of 0.99. Moreover, the NiO nanostructures based sensor is highly reproducible, stable, exhibiting a fast response time and selective in the response. All the obtained results indicate the potential use of this material in the development of enzyme free sensors for the detection of glucose.
- Z. Yang, J. Feng, J. Qiao, Y. Yan, Q. Yu and K. Sun, “Copper Oxide Nanoleaves Decorated Multi-Walled Carbon Nanotube as Platform for Glucose Sensing,” Analytical Methods, Vol. 4, No. 7, 2012, pp. 1924-1926. http://dx.doi.org/10.1039/c2ay25283j
- G. P. Hicks and S. J. Updike, “The Enzyme Electrode,” Nature, Vol. 214, 1967, pp. 986-988. http://dx.doi.org/10.1038/214986a0
- L. Hu, S. Han, Z. Liu, S. Parveen, Y. Yuan and G. Xu, “A Versatile Strategy for Electrochemical Detection of Hydrogen Peroxide as well as Related Enzymes and Substrates Based on Selective Hydrogen Peroxide-Mediated Boronate Deprotection,” Electrochemistry Communication, Vol. 13, No. 12, 2011, pp. 1536-1538. http://dx.doi.org/10.1016/j.elecom.2011.10.016
- A. M. Vinu Mohan, K. K. Ashwini, A. Maria Starvin and V. M. Biju, “Amperometric Detection of Glucose Using Prussian Blue-Graphene Oxide Modified Platinum Electrode,” Analytical Methods, Vol. 5, No. 7, 2013, pp. 1764-1770. http://dx.doi.org/10.1039/c3ay26310j
- V. Mani, B. Devadas and S. M. Chen, “Direct Electrochemistry of Glucose Oxidase at Electrochemically Reduced Graphene Oxide-Multiwalled Carbon Nanotubes Hybrid Material Modified Electrode for Glucose Biosensor,” Biosensor Bioelectronic, Vol. 41, 2013, pp. 309-315. http://dx.doi.org/10.1016/j.bios.2012.08.045
- A. Sun, J. Zheng and Q. Sheng, “A Highly Sensitive Non-Enzymatic Glucose Sensor Based on Nickel and Multi-Walled Carbon Nanotubes Nanohybrid Films Fabricated by One-Step Co-Electrodeposition in Ionic Liquids,” Electrochimca Acta, Vol. 65, 2012, pp. 64-69. http://dx.doi.org/10.1016/j.electacta.2012.01.007
- Y. Mu, D. Jia, Y. He, Y. Miao and H. L. Wu, “Nano Nickel Oxide Modified Non-Enzymatic Glucose Sensors with Enhanced Sensitivity through an Electrochemical Process Strategy at High Potential,” Biosensor Bioelectronics, Vol. 26, No. 6, 2011, pp. 2948-2952. http://dx.doi.org/10.1016/j.bios.2010.11.042
- C. Guo, Y. Wang, Y. Zhao and C. Xu, “Non-Enzymatic Glucose Sensor Based on Three Dimensional Nickel Oxide for Enhanced Sensitivity,” Analytical Methods, Vol. 5, No. 7, 2013, pp. 1644-1647. http://dx.doi.org/10.1039/c3ay00067b
- J. Chen, W. D. Zhang and J. S. Ye, “Nonenzymatic Electrochemical Glucose Sensor Based on MnO2/MWNTs Nanocomposite,” Electrochemistry Communications, Vol. 10, No. 9, 2008, pp. 1268-1271. http://dx.doi.org/10.1016/j.elecom.2008.06.022
- X. Wang, X. Dong, Y. Wen, C. Li, Q. Xiong and P. Chen, “A Graphene-Cobalt Oxide Based Needle Electrode for Non-Enzymatic Glucose Detection in Micro-Droplets,” Chemical Communication, Vol. 48, No. 52, 2012, pp. 6490-6492. http://dx.doi.org/10.1039/c2cc32674d