Treatment of reverse oblique trochanteric femoral fractures poses a lot of challenges. There have been proponents of intramedullary devices as well as extramedullary devices. We present the results of proximal femoral nailing surgery performed for reverse obliquity intertrochanteric fractures using two proximal lag screws and a nail of 250 mm. There is prospective study of fifty three patients with AO/OTA 31 A-A3 fractures being treated by proximal femoral nailing in our institute after seeking approval from the Hospital ethics board. The quality of the reduction, the operative time, complications and the functional status of the patients were the parameters on which the results were evaluated. The mean Harris hip score was 76 .66 (range 70 - 93) and the mean Barthel activity score was 16 .21 (range 12 - 20). The average surgical time was 50 minutes and the mean consolidation time was 11.5 weeks . Intramedullary nailing with proximal femoral nails seems to be a good option in the treatment of reverse obliquity intertrochanteric fractures as against the various existing options available for the management.
Domingo, L., Cecillia, D., Herrera, A., et al. (2001) Trochanteric Fractures Treated with a Proximal Femoral Nail. International Orthopaedics, 25, 298-301. http://dx.doi.org/10.1007/s002640100275
Haldar, S.C. (1992) The Gamma Nail for Pertrochanteric Fractures. The Journal of Bone & Joint Surgery, 74-B, 340-344.
Leung, K.S., So, W.S., Shen, W.Y., et al. (1992) Gamma Nails and Dynamic Hip Screws for Pertrochanteric Fractures. The Journal of Bone & Joint Surgery, 74-B, 345-351.
Banan, H., Al-Sabti, A., Jimulia, T. and Hart, A.J. (2002) The Treatment of Unstable Extracapsuler Hip Fractures with AO/ASIF Proximal Femoral Nail (PFN)—Our First 60 Cases. Injury, 33, 401-405. http://dx.doi.org/10.1016/S0020-1383(02)00054-2
Boldin, C., Seibert, F.J., Frankhauser, F., et al. (2003) The Proximal Femoral Nail (PFN)—A Minimal Invasive Treatment of Unstable Proximal Femoral Fractures: A Prospective Study of 55 Patients with a Follow-Up of 15 Months. Acta Orthopaedica Scandinavica, 74, 53-58. http://dx.doi.org/10.1080/00016470310013662
Ozkan, K., Eceviz, E., Unay, K., et al. (2011) Treatment of Reverse Oblique Trochanteric Femoral Fractures with Proximal Femoral Nail. International Orthopaedics, 35, 595-598. http://dx.doi.org/10.1007/s00264-010-1002-z
Gadegone, W.M. and Salphale, Y.S. (2007) Proximal Femoral Nail—An Analysis of 100 Cases of Proximal Femoral Fractures with an Average Follow up of 1 Year. International Orthopaedics, 31, 403-408. http://dx.doi.org/10.1007/s00264-006-0170-3
Matre, K., Havelin, L.I., Gjertsen, J.E., Vinje, T., Espehaug, B. and Fevang, J.M. (2013) Sliding Hip Screw versus IM Nail in Reverse Oblique Trochanteric and Subtrochanteric Fractures. A Study of 2716 Patients in the Norwegian Hip Fracture Register. Injury, 44, 735-742. http://dx.doi.org/10.1016/j.injury.2012.12.010
Rosenblum, S.F., Zuckerman, J.D., Kummer, F.J. and Tam, B.S. (1992) A Biomechanical Evaluation of the Gamma Nail. The Journal of Bone and Joint Surgery, British Volume, 74, 352-357.
Hoskins, W., Bingham, R., Joseph, S., Liew, D., Love, D., Bucknill, A., Oppy, A. and Griffin, X. (2015) Subtrochanteric Fracture: The Effect of Cerclage Wire on Fracture Reduction and Outcome. Injury, 46, 1992-1995. http://dx.doi.org/10.1016/j.injury.2015.07.001
Müller, T., Topp, T., Kühne, C.A., Gebhart, G., Ruchholtz, S. and Zettl, R. (2011) The Benefit of Wire Cerclage Stabilisation of the Medial Hinge in Intramedullary Nailing for the Treatment of Subtrochanteric Femoral Fractures: A Biomechanical Study. International Orthopaedics, 35, 1237-1243. http://dx.doi.org/10.1007/s00264-010-1204-4
Afsari, A., Liporace, F., Lindvall, E., Infante Jr., A., Sagi, H.C. and Haidukewych, G.J. (2010) Clamp-Assisted Reduction of High Subtrochanteric Fractures of the Femur: Surgical Technique. The Journal of Bone and Joint Surgery, American Volume, 92, 217-225.
Gotfried, Y. (2007) Integrity of the Lateral Femoral Wall in Intertrochanteric Hip Fractures: An Important Predictor of a Reoperation. The Journal of Bone and Joint Surgery, American Volume, 89, 2552-2553.
Hu, S.-J., Zhang, S.-M. and Yu, G.-R. (2012) Treatment of Femoral Subtrochanteric Fractures with Proximal Lateral Femur Locking Plates. Acta Ortopédica Brasileira, 20, 329-333. http://dx.doi.org/10.1590/S1413-78522012000600003
Egol, K.A., Kubiak, E.N., Fulkerson, E., Kummer, F.J. and Koval, K.J. (2004) Biomechanics of Locked Plates and Screws. Journal of Orthopaedic Trauma, 18, 488-493. http://dx.doi.org/10.1097/00005131-200409000-00003
Kregor, P.J., Obremsky, W.T., Kreder, H.J. and Swiontkowski, M.F. (2005) Evidence-Based Orthopaedic Trauma Working Group. Unstable Pertrochanteric Femoral Fractures. Journal of Orthopaedic Trauma, 19, 63-66. http://dx.doi.org/10.1097/00005131-200501000-00014
Sadowski, C., Labbeke, A., Saudan, M., Riand, N., Stern, R. and Hoffmeyer, P.J. (2002) Treatment of Reverse Oblique and Transverse Intertrochanteric Fractures with Use of an Intramedullary Nail or a 95 Degrees Screw-Plate: A Prospective, Randomized Study. The Journal of Bone & Joint Surgery, 84-A, 372-381.
Garnavos, C., Peterman, A. and Howard, P. (1999) The Treatment of Difficult Proximal Femoral Fractures with the Russell-Taylor Reconstruction Nail. Injury, 30, 407-415. http://dx.doi.org/10.1016/S0020-1383(99)00107-2
Korkmaz, M.F., Erdem, M.N., Disli, Z., Selcuk, E.B., Karakaplan, M. and Gogus, A. (2014) Outcomes of Trochanteric Femoral Fractures Treated with Proximal Femoral Nail: An Analysis of 100 Consecutive Cases. Clinical Interventions in Aging, 9, 569-574.
Park, S.Y., Yang, K.H., Yoo, J.H., Yoon, H.K. and Park, H.W. (2008) The Treatment of Reverse Obliquity Intertrochanteric Fractures with the Intramedullary Hip Nail. The Journal of Trauma, 65, 852-857. http://dx.doi.org/10.1097/TA.0b013e31802b9559
Okcu, G., Ozkayin, N., Okta, C., Topcu, I. and Aktuglu, K. (2013) Which Implant Is Better for Treating Reverse Obliquity Fractures of the Proximal Femur: A Standard or Long Nail? Clinical Orthopaedics and Related Research, 471, 2768-2775. http://dx.doi.org/10.1007/s11999-013-2948-0
Ongkiehong, B.F. and Leemans, R. (2007) Proximal Femoral Nail Failure in a Subtrochanteric Fracture: The Importance of Fracture to Distal Locking Screw Distance. Injury Extra, 38, 445-450. http://dx.doi.org/10.1016/j.injury.2007.03.015
Sommers, M.B., Roth, C., Hall, H., et al. (2004) A Laboratory Model to Evaluate Cut out Resistance of Implants for Pertrochanteric Fracture Fixation. Journal of Orthopaedic Trauma, 18, 361-368. http://dx.doi.org/10.1097/00005131-200407000-00006
Marmor, M., Liddle, K., Buckley, J. and Matityahu, A. (2016) Effect of Varus and Valgus Alignment on Implant Loading after Proximal Femur Fracture Fixation. European Journal of Orthopaedic Surgery & Traumatology, 26, 379-383. http://dx.doi.org/10.1007/s00590-016-1746-2