The object of this review is to examine the role of TEVAR in causing SCI. The anatomy and physiology of blood flow to the spinal cord is examined. The role of auto regulation of blood flow within the spinal cord is also examined. This review examines the reported results from the scientific literature of the effect of thoracic aortic aneurysm repair on spinal cord blood flow. In the light of the-se findings several conclusions can reasonably be reached. These conclusions are that the development of SCI can reasonably be predicted based on complexity and extent of the TEVAR procedure performed and BP augmentation and CSF drainage can significantly reduce the impact of SCI.
Griepp, R.B. and Griepp, E.B. (2007) Spinal Cord Perfusion and Protection during Descending Thoracic and Thoracoabdominal Surgery: The Collateral Network Concept. The Annals of Thoracic Surgery, 83, S865-S869. https://doi.org/10.1016/j.athoracsur.2006.10.092
Lazorthes, G., Gouaze, A., Zadeh, J.O., et al. (1971) Arterial Vascularisation of the Spinal Cord: Recent Studies of the Anatomic Substitution Pathways. Journal of Neurosurgery, 35, 253-262. https://doi.org/10.3171/jns.1971.35.3.0253
Klaric, M. and Oreskovic, D. (2014) A New Look at Cerebrospinal Fluid Movement. Fluid Barriers CNS, 11.
Papadopoulos, M.C. and Verkman, A.S. (2013) Aquaporin Water Channels in the Nervous System. Nature Reviews Neuroscience, 14, 265-277. https://doi.org/10.1038/nrn3468
Ishmura, S., Kawaguchi, S., Koizumi, N., Obitsu, Y. and Ishikawa, M. (1998) Preliminary Report on Prediction of Spinal Cord Ischemia in Endovascular Stent Graft Repair of Thoracic Aortic Aneurysm by Retrievable Stent Graft. Journal of Thoracic and Cardiovascular Surgery, 115, 811-818. https://doi.org/10.1016/S0022-5223(98)70360-5
Gravereaux, E.C., Faries, P.L., Burks, J.A., et al. (2001) Risk of Spinal Cord Ischemia after Endograft Repair of Thoracic Aortic Aneurysms. Journal of Vascular Surgery, 34, 997-1003 https://doi.org/10.1067/mva.2001.119890
Chiesa, R., Melissano, G., et al. (2005) Spinal cord Ischemia after Elective Stent-Graft Repair of the Thoracic Aorta. Journal of Vascular Surgery, 42, 11-17.
Buth, J., Harris, P.L., Hobo, R., et al. (2007) Neurological Complications Associated with Endovascular Repair of Thoracic Pathology: Incidence of Risk Factors. A Study from the European Collaborators on Stent/Graft Repair (Eurostar) Registry. Journal of Vascular Surgery, 46, 1103-1111. https://doi.org/10.1016/j.jvs.2007.08.020
Kawaharada, N., Morishita, K., Kurimoto, Y., et al. (2007) Spinal Cord Ischemia after Elective Endovascular Stent Graft Repair of the Thoracic Aorta. European Journal Cardio-Thoracic Surgery, 31, 998-1003. https://doi.org/10.1016/j.ejcts.2007.01.069
Amabile, P., Grisoli, D., Giorgi, R., et al. (2008) Incidence and Determinants of Spinal Cord Ischemia in Stent Graft Repair of the Thoracic Aorta. European Journal of Vascular and Endovascular Surgery, 35, 455-461. https://doi.org/10.1016/j.ejvs.2007.11.005
Feezor, R.J., Martin, T.D., Hess, P.J., et al. (2008) Extent of Aortic Coverage and Incidence of Spinal Cord Ischemia after Thoracic Endovascular Aneurysm Repair. Annals of Thoracic Surgery, 86, 1809-1814. https://doi.org/10.1016/j.athoracsur.2008.09.022
Greenberg, R.K., Lu, Q., Roselli, E.E., et al. (2008) Contemporary Analysis of Descending Thoracic and Thoracoabdominal Aneurysm Repair. A Comparison of Endovascular and Open Techniques. Circulation, 118, 808-817. https://doi.org/10.1161/CIRCULATIONAHA.108.769695
Drinkwater, S.L., Goebells, A., Haydar, A., et al. (2010) The Incidence of Spinal Cord Ischemia Following Thoracic and Thoracoabdominal Aortic Endovascular Intervention. European Journal of Vascular and Endovascular Surgery, 40, 729-735. https://doi.org/10.1016/j.ejvs.2010.08.013
Ullery, B.W., Cheung, A.T., Fairman, R.M., et al. (2011) Risk Factors, Outcome, and Clinical Manifestations of Spinal Cord Ischemia Following Thoracic Endovascular Repair. Journal of Vascular Surgery, 54, 677-684. https://doi.org/10.1016/j.jvs.2011.03.259
Sullivan, T.M. and Sundt, T.M. (2006) Complication of Thoracic Aortic Endografts: Spinal Cord Ischemia and Stroke. Journal of Vascular Surgery, 43, 85a-88a. https://doi.org/10.1016/j.jvs.2005.10.048
Etz, C.D., Halstead, C.D., Spielvogel, D., et al. (2006) Thoracic and Thoracoabdominal Aneurysm Repair: Is Reimplantation of Spinal Cord Arteries a Waste of Time. Annals of Thoracic Surgery, 82, 1670-1678. https://doi.org/10.1016/j.athoracsur.2006.05.029
Bavaria, J.E., Appoo, J.J., Makaroun, M.S., et al. (2007) Endovascular Stent Grafting versus Open Surgical Repair of Thoracic Aortic Aneurysms in Low Risk Patients: A Multicentre Comparative Trial. The Journal of Thoracic and Cardiovascular Surgery, 133, 369-377. https://doi.org/10.1016/j.jtcvs.2006.07.040
Conrad, M.F., Crawford, R.S., Davison, K., et al. (2007) Thoracoabdominal Aneurysm Repair: A Twenty Year Experience. Annals of Thoracic Surgery, 83, s856-s861. https://doi.org/10.1016/j.athoracsur.2006.10.096
Matsumura, J.S., Cambria, R.P., Dake, M.D., et al. (2008) International Controlled Trial of Thoracic Endovascular Aneurysm Repair with the Zenith TX2 Endovascular Graft: 1 Year Results. Journal of Vascular Surgery, 47, 247-257. https://doi.org/10.1016/j.jvs.2007.10.032
Cunningham, J.N., Laschinger, J.C., Merkin, H.A., Coselli, J.S. and Safi, H. (1982) Measurement of Spinal Cord Ischemia during Operations on the Thoracic Aorta. Annals of Surgery, 196, 285-293. https://doi.org/10.1097/00000658-198209000-00007
Svennson, L.G., Crawford, E.S., Hess, K.R., et al. (1993) Experience with 1509 Patients Undergoing Thoracoabdominal Aortic Aneurysm Operations. Journal of Vascular Surgery, 17, 357-370. https://doi.org/10.1016/0741-5214(93)90421-H
Livesay, J.L., Cooley, D.A., Ventemiglia, R.A. et al. (1995) Surgical Experience in Descending Thoracic Aneurysmectomy with and without Adjuncts to Avoid Ischemia. Annals of Thoracic Surgery, 39, 37-46. https://doi.org/10.1016/S0003-4975(10)62520-9
Coselli, J.S., LeMaire, S.A., Conklin, L.D. and Adams, G. (2004) Left Heart Bypass during Descending Thoracic Aortic Aneurysm Repair Does Not Reduce the Incidence of Paraplegia. Annals of Thoracic Surgery, 77, 1298-1303. https://doi.org/10.1016/j.athoracsur.2003.10.033
Cambria, R.P., Davison, J.K., Carter, C., et al. (2000) Epidural Cooling for Spinal Cord Protection during Thoracoabdominal Aneurysm Repair: A Five Year Experience. Journal of Vascular Surgery, 31, 1093-1102. https://doi.org/10.1067/mva.2000.106492
Hnath, J.C., Metha, M., Taggert, J.B., et al. (2008) Strategies to Improve Spinal Cord Ischemia in Endovascular Thoracic Aortic Repair: Outcomes of a Prospective Cerebrovascular Fluid Drainage Protocol. Journal of Vascular Surgery, 48, 836-840. https://doi.org/10.1016/j.jvs.2008.05.073
Cheung, A.T., Pochettino, A., McGarvey, M.L., et al. (2005) Strategies to Manage Paraplegia Risk after Endovascular Stent Repair of Descending Thoracic Aortic Aneurysms. Annals of Thoracic Surgery, 80, 1280-1289. https://doi.org/10.1016/j.athoracsur.2005.04.027
Cina, C.S., Abouzahr, L., Arena, G.O., et al. (2004) Cerebrospinal fluid drainage to prevent paraplegia during thoracic and thoracoabdominal aneurysm surgery: A systematic review and meta-analysis. Journal of Vascular Surgery, 40, 36-44. https://doi.org/10.1016/j.jvs.2004.03.017
Estrera, A.L., Shienbaum, R., Miller, C.C., et al. (2009) Cerebrospinal Fluid Drainage during Thoracic Aortic Repair: Safety and Current Management. Annals of Thoracic Surgery, 88, 9-15. https://doi.org/10.1016/j.athoracsur.2009.03.039
Wynn, M.M., Mell, M.W., Tefera, G., Hoch, J. and Acher, C. (2009) Complications of Spinal Fluid Drainage in Thoracoabdominal Aortic Aneurysm Repair: A Report of 486 Patients Treated from 1987 to 2008. Journal of Vascular Surgery, 49, 29-35. https://doi.org/10.1016/j.jvs.2008.07.076