A Prospective, Within-Patient Controlled Study to Compare the Ability of the Non Adherent Drawtex® Hydroconductive Dressing to a Transparent Polyurethane Film Dressing (Standard of Care) on the Healing of Split-Thickness Skin Graft Donor Sites*
- 1 Department of Surgery, Division of Plastic & Reconstructive Surgery, School of Clinical Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- 2 Department of Surgery, School of Clinical Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- 3 Department of Surgery, School of Clinical Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- 4 Department of Surgery, School of Clinical Medicine, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
- 5 Department of Surgery, University of South Florida, Tampa, FL, USA
Abstract
Background: Dressing of split-thickness skin graft donor sites can be traumatic for the patient. The most advan ced an d expensive dressings have been compared to the most basic of dressings, with little or no consensus and an unpersuasive level of evidence. We aimed to determine the efficacy of the locally manufactured non-adherent, hydroconductive Drawtex ? dressing and compare it to our current standard-of-care dressing, a thin transparent polyurethane film, in the healing of split-thickness donor sites. Methods: This prospective, within-patient controlled study included 27 adult participants, each with two split-thickness skin donor sites. The 54 donor site wounds were compared with regard to time to re-epithelialisation, perceived pain and healed wound quality. Results: By day 5, complete healing of donor site wounds, defined as >90% of epithelialized surface, was significantly higher in the hydroconductive dressing group compared to the polyurethane film group (22.2% and 3.7%, respectively; p < 0.0001). The hydroconductive dressing-treated donor site wounds were significantly less painful at 24-hours, 48-hours and 7-days post-operatively, and had fewer complications and superior wound healing quality. Conclusion: We have demonstrated that the relatively cheap and readily available dressing made locally in South Africa, Drawtex ? is at least as safe, and potentially superior in wound healing, when compared to our current standard-of-care dressing.
- Innes, M.E., Umraw, N., Fish, J.S., Gomez, M. and Cartotto, R.C. (2001) The Use of Silver Coated Dressings on Donor Site Wounds: A Prospective, Controlled Matched Pair Study. Burns, 27, 621-627. https://doi.org/10.1016/S0305-4179(01)00015-8
- Ma, B., Cheng, D.S., Xia, Z.F., Ben, D.F., Lu, W., Cao, Z.F., et al. (2007) Randomized, Multicenter, Double-Blind, and Placebo-Controlled Trial Using Topical Recombinant Human Acidic Fibroblast Growth Factor for Deep Partial-Thickness Burns and Skin Graft Donor Site. Wound Repair and Regeneration, 15, 795-799. https://doi.org/10.1111/j.1524-475X.2007.00307.x
- Rakel, B.A., Bermel, M.A., Abbott, L.I., Baumler, S.K., Burger, M.R., Dawson, C.J., et al. (1998) Split-Thickness Skin Graft Donor Site Care: A Quantitative Synthesis of the Research. Applied Nursing Research, 11, 174-182. https://doi.org/10.1016/S0897-1897(98)80296-6
- Kazanavicius, M., Cepas, A., Kolaityte, V., Simoliuniene, R. and Rimdeika, R. (2017) The Use of Modern Dressings in Managing Split-Thickness Skin Graft Donor Sites: A Single-Centrerandomised Controlled Trial. Journal of Wound Care, 26, 281-291. https://doi.org/10.12968/jowc.2017.26.6.281
- James, J.H. and Watson, A.C. (1975) The Use of Opsite, A Vapour Permeable Dressing, on Skin Graft Donor Sites. British Journal of Plastic Surgery, 28, 107-110.
- Fernandes de Carvalho, V., Paggiaro, A.O., Isaac, C., Gringlas, J. and Ferreira, M.C. (2011) Clinical Trial Comparing 3 Different Wound Dressings for the Management of Partial-Thickness Skin Graft Donor Sites. Journal of Wound, Ostomy and Continence Nursing, 38, 643-647. https://doi.org/10.1097/WON.0b013e3182349d2f
- Hu, Z., Guo, D., Liu, P., Cao, X., Li, S., Zhu, J. and Tang, B. (2017) Randomized Clinical Trial of Autologous Skin Cell Suspension for Accelerating Re-Epithelialization of Split-Thickness Donor Sites. British Journal of Surgery, 104, 836-842. https://doi.org/10.1002/bjs.10508
- Subrahmanyam, M. (2015) Honey Dressing Accelerates Split-Thickness Skin Graft Donor Site Healing. Indian Journal of Surgery, 77, 261-263. https://doi.org/10.1007/s12262-012-0789-9
- Tanaka, K., Akita, S., Yoshimoto, H., Houbara, S. and Hirano, A. (2014) Lipid-Colloid Dressing Shows Improved Reepithelialization, Pain Relief, and Corneal Barrier Function in Split-Thickness Skin-Graft Donor Wound Healing. International Journal of Lower Extremity Wounds, 13, 220-225. https://doi.org/10.1177/1534734614541544
- Lairet, K.F., Baer, D., Leas, M.L., Renz, E.M. and Cancio, L.C. (2014) Evaluation of an Oxygen-Diffusion Dressing for Accelerated Healing of Donor-Site Wounds. Journal of Burn Care & Research, 35, 214-218. https://doi.org/10.1097/BCR.0b013e31829b3338