Fluid Vibration Induced in T-Junction with Double Side Branches
- 1 Graduate School of Engineering, Chiba University, Chiba, Japan
- 2 Graduate School of Engineering, Chiba University, Chiba, Japan
- 3 Graduate School of Engineering, Chiba University, Chiba, Japan
- 4 Institute of Fluid Science, Tohoku University, Sendai, Japan
Abstract
A T-junction is a fundamental fluid element prevalent in pipe networks of water supplies and power plants. In the present study, a double T-junction was investigated for flow instability and fluid vibration. Both axi-aligned and skewed double T-junctions are examined from viewpoint of flow instability. With single-phase flow in an open-ended double T-junction, fluid vibration is induced in both side branches because of a high shear rate with a point of inflection. The frequency of vibration in the downstream branch is higher than that in the upstream branch. Except for the upstream branch in the skewed double T-junction, the frequency is higher than that in a single T-junction. The fluid vibrations are closely associated with the fluid interference created by the presence of the two side branches.
- Kondo, S. (1991) Lessons Learned for PSA from the SGTR Incident at Mihama, Unit 2. Reliability Engineering & System Safety, 45, 57-65.
- Brown, G.L. and Roshko, A. (1974) On Density Effects and Large Structure in Turbulence Mixing Layers. Journal of Fluid Mechanics, 64, 775-816. http://dx.doi.org/10.1017/S002211207400190X
- Tani, I. (1964) Low-Speed Flows Involving Bubble Separation. Progress in Aeronautical Sciences, 5, 79-103. http://dx.doi.org/10.1016/0376-0421(64)90004-1
- Sarohia, V. (1977) Experimental Investigation of Oscillations Flows over Shallow Cavities. AIAA Journal, 15, 984-991.
- Rockwell, D. and Naudascher, E. (1978) Review-Self-Sustaining Oscillations of Flow past Cavities. Journal of Fluids Engineering, 100, 152-165. http://dx.doi.org/10.1115/1.3448624
- Sherwin, S.J. and Blackburn, H.M. (2005) Three-Dimensional Instabilities and Transition of steady and Pulsatile Axisymmetric Stenotic Flows. Journal of Fluid Mechanics, 533, 297-327. http://dx.doi.org/10.1017/S0022112005004271
- Mori, T. and Nagamura, K. (2010) LDV and PIV Measurements of the Organized Oscillations of Turbulent Flow over a Rectangular Cavity. Journal of Fluid Science and Technology, 5, 370-383. http://dx.doi.org/10.1299/jfst.5.370
- Yagi, T., Sato, A., Shinke, M., et al., 2013.Experimental Insights into Flow Impingement in Cerebral Aneurysm by Stereoscopic Particle Image Velocimetry: Transition from a Laminar Regime. Journal of the Royal Society Interface, 10. http://dx.doi.org/10.1098/rsif.2012.1031
- Valen-Sendstad, K., Mardal, K-A., Mortensen, M., et al. (2011) Direct Numerical Simulation of Transitional Flow in a Patient-Specific Intracranial Aneurysm. Journal of Biomechanics, 44, 2826-2832. http://dx.doi.org/10.1016/j.jbiomech.2011.08.015
- Valen-Sendstad, K., Mardal, K.-A. and Steinman, D.A. (2013) High-Resolution CFD Detects High-Frequency Velocity Fluctuations in Bifurcation, but not Sidewall Aneurysms. Journal of Biomechanics, 46, 402-407. http://dx.doi.org/10.1016/j.jbiomech.2012.10.042
- Valen-Sendstad, K., Piccinelli, M. and Steinman, D.A. (2014) High-Resolution Computational Fluid Dynamics Detects Flow Instabilities in the Carotid Siphon: Implications for Aneurysm Initiation and Rupture? Journal of Biomechanics, 47, 3210-3216. http://dx.doi.org/10.1016/j.jbiomech.2014.04.018
- Il’ichev, A.T., Fu, Y-B, 2012. Stability of Aneurysm Solutions in a Fluid-Filled Elastic Membrane Tube. Acta Mechanica Sinica, 28, 1209-1218. http://dx.doi.org/10.1007/s10409-012-0135-2