Effect of Titanium Dioxide Nano Particles Incorporation on Mechanical and Physical Properties on Two Different Types of Acrylic Resin Denture Base
- 1 Prosthodontics Department, Faculty of Dentistry, Taif University, Taif, Saudi Arabia
- 2 Mechanical Engineering Department, Engineering College, Taif University, Taif, Saudi Arabia
- 3 Preventive Department, Faculty of Dentistry, Taif University, Taif, Saudi Arabia
- 4 Mechanical Engineering Department, Engineering College, Taif University, Taif, Saudi Arabia
Abstract
The aim of this study is to clarify the effect of different concentrations of titanium dioxide nanoparticles (Nps) on the properties of two types of heat polymerized acrylic resin. The tested parameters were flexural strength, impact strength, and microhardness. The two types of acrylic resin used in this study were conventional unmodified (Implacryl, Vertex) and high impact heat polymerized acrylic resin (Vertex-Dental, Netherlands). Both types of acrylic resin were modified by using 1% and 5% TiO 2 Nps powder. Specimen’s dimensions were prepared according to the American Dental Association Specification No. 12. Three types of specimens were prepared: 1) flexural strength specimens 50 mm × 10 (±0.2) mm × 3 (±0.2) mm, 2) impact strength test specimens 60 mm × 6.0 mm × 4.0 mm, 3) microhardnesss specimens 25 mm × 10 mm × 3 (±0.2) mm. For each test 6 groups were prepared (each group containing 5 samples). Thirty specimens were prepared in each of the three tests, amounting to a total number of 90 specimens. Mechanical properties such as flexural strength (FS), impact strength and microhardness of the above mentioned specimens were determined using universal testing machine, Izod pendulum impact testing machine and Vickers microhardness tester, respectively. ISO Specification No. 1567 was followed in microhardness test. The data was collected and statistically analyzed. Flexural strength considerably decreased by increasing TiO 2 concentration in both types of acrylic resin. Impact strength of the conventional acrylic resin modified by 1% of additives significantly increased. The microhardness is significantly increased by addition of 5% of TiO 2 Nps. The Incorporation of TiO 2 nanoparticles into acrylic resins can adversely affect its flexural strength. Meanwhile, the impact strength can be modified by small percentage of additives (abt. 1%). This effect is directly correlated with the concentration of nanoparticles. On the other hand, concentrations of TiO 2 Nps (abt. 5%) positively affect the microhardness of both types of acrylic resin used in the present study.
- Elshereksi, N.W., Ghazali, M.J., Muchtar, A. and Azhari, C.H. (2014) Perspectives for Titanium-Derived Fillers Usage on Denture Base Composite Construction: A Review Article. Advances in Materials Science and Engineering, 2014, Article ID: 746252. http://dx.doi.org/10.1155/2014/746252
- Ahmed, M.A. and Ebrahim, M.I. (2014) Effect of Zirconium Oxide Nano-Fillers Addition on the Flexural Strength, Fracture Toughness, and Hardness of Heat-Polymerized Acrylic Resin. World Journal of Nano Science and Engineering, 4, 50-57. http://dx.doi.org/10.4236/wjnse.2014.42008
- Hamouda, I.M. and Beyari, M.M. (2014) Addition of Glass Fibers and Titanium Dioxide Nanoparticles to the Acrylic Resin Denture Base Material: Comparative Study with the Conventional and High Impact Types. Oral Health and Dental Management, 13, 107-112.
- Mowade, T.K., Dange, S.P., Thakre, M.B. and Kamble, V.D. (2012) Effect of Fiber Reinforcement on Impact Strength of Heat Polymerized Polymethyl Methacrylate Denture Base Resin: In Vitro Study and SEM Analysis. Journal of Advanced Prosthodontics, 4, 30-36. http://dx.doi.org/10.4047/jap.2012.4.1.30
- Vallo, C.I., Abraham, G.A., Cuadrado, T.R. and Román, J.S. (2004) Influence of Cross-Linked PMMA Beads on the Mechanical Behavior of Self-Curing Acrylic Cements. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 70B, 407-416. http://dx.doi.org/10.1002/jbm.b.30054
- Sasaki, H., Hamanaka, I., Takahashi, Y. and Kawaguchi, T. (2015) Effect of Reinforcement on the Flexural Properties of Injection-Molded Thermoplastic Denture Base Resins. Journal of Prosthodontics. http://dx.doi.org/10.1111/jopr.12419
- Shirkavand, S. and Moslehifard, E. (2014) Effect of TiO2 Nanoparticles on Tensile Strength of Dental Acrylic Resins. Journal of Dental Research, Dental Clinics, Dental Prospects, 8, 197-203.
- Reijnders, L. (2009) The Release of TiO2 and SiO2 Nanoparticles from Nanocomposites. Polymer Degradation and Stability, 94, 873-876. http://dx.doi.org/10.1016/j.polymdegradstab.2009.02.005
- Chatterjee, A. (2010) Properties Improvement of PMMA Using Nano TiO2. Journal of Applied Polymer Science, 18, 2890-2897. http://dx.doi.org/10.1002/app.32567
- Sodagar, A., Bahador, A., Khalil, S., Shahroudi, A.S. and Kassaee, M.Z. (2013) The Effect of TiO2 and SiO2 Nanoparticles on Flexural Strength of Poly(methyl methacrylate) Acrylic Resins. Journal of Prosthodontic Research, 57, 15-19. http://dx.doi.org/10.1016/j.jpor.2012.05.001