Cause Analysis for Wall Thinning of Small-Bore Piping in Nuclear Power Plant by ToSPACE, FLUENT and Theoretical Evaluation
- 1 KEPCO E&C, Gimcheon-si, Korea
- 2 KEPCO E&C, Gimcheon-si, Korea
- 3 KEPCO E&C, Gimcheon-si, Korea
Abstract
It has been known that FAC, LDIE, cavitation and flashing are the damage mechanisms that can cause the pipe thickness of the secondary system of nuclear power plants thinner. Severe wall thinning was found in the MSR drain pipes at a Korean nuclear power plant a decade ago, and all the affected pipes were replaced with low alloy steel with higher chromium contents. Therefore, this study was conducted to reduce the possibility of similar thinning cases that may occur in the future by identifying the exact cause of thinning. ToSPACE and FLUENT codes and theoretical evaluation method were applied to analyze the causes of thinning. ToSPACE and FLUENT analyses and theoretical evaluation including all the operating conditions show a relatively large pressure drop and a pressure lower than the saturated vapor pressure in common at the end of the pipe entering the condenser. This means that flashing occurs at the end of the pipe under all operating conditions, and the effect can be greater than that of other parts. As a result, since severe wall thinning occurred at the end of the pipeline entering the condenser, it was evaluated that flashing by the high-velocity two-phase fluid was the direct cause of the wall thinning in the MSR drain pipes. The results of this study will contribute to establishing appropriate countermeasures in the event of pipe wall thinning in the future.
- EPRI (2004) Recommendations for Controlling Cavitation, Flashing, Liquid Droplet Impingement, and Solid Particle Erosion in Nuclear Power Plant Piping Systems, 1011231, Final Report.
- Hwang, K.M., Seo, H.K., Lee, C.K. and Nam, W.C. (2017) Development of LDIE Prediction Theory in the Condition of Magnetite Formation on Secondary Side Piping in Nuclear Power Plants. World Journal of Nuclear Science and Technology, 7, 1-14. https://doi.org/10.4236/wjnst.2017.71001
- Hwang, K.M., Lee, D.J., Yun, H., Yoo, S.C. and Kim, J.H., (2022) Analysis of Material Loss Behavior According to Long-Term Experiments on LDIE-FAC Multiple Degradation of Carbon Steel Materials. World Journal of Nuclear Science and Technology, 12, 1-10. https://doi.org/10.4236/wjnst.2022.121001
- Hwang, K.M., Yun, H., Seo. H.K., Lee. G.Y. and Kim, K.W. (2019) Development of ToSPACE for Pipe Wall Thinning Management in Nuclear Power Plants. World Journal of Nuclear Science and Technology, 9, 1-15. https://doi.org/10.4236/wjnst.2019.91001
- EPRI (1993) A Method to Predict Cavitation and the Extent of Damage in Power Plant Piping—Tier 1: Cavitation Erosion Model, TR-103198-T1, Final Report.
- EPRI (1993) A Method to Predict Cavitation and the Extent of Damage in Power Plant Piping—Tier 2: Cavitation Coefficients, TR-103198-T2, Final Report.