The laboratory of Radiation Dosimetry and Calibration of the Belgian Nuclear Research Centre (SCK.CEN) is using thermoluminescence dosimetry for more than thirty years for routine measurements and for R&D investigations. In 2002, it has developed an experimental device based on the optically stimulated luminescence (OSL) technique. This device is working with AL2O3:C crystals stimulated by the green line (488 nm) emitted by a 150 mW argon laser. This paper describes this device, its characteristics, some applications in space dosimetry and the R&D works initiated in this field during the next few years.
KeywordsExternal DosimetryOSLOptically Stimulated Dosimetry
- S. W. S. McKeever, M. S. Akselrod and B. G. Markey, “Pulsed Optically Stimulated Luminescence Dosimetry Using α-Al2O3:C,” Radiation Proection Dosimetry, Vol. 65, No. 1-4, 1996, pp. 267-272.
- V. V. Antonov-Romanovskii, I. F. Keirum-Marcus, M. S. Poroshina and Z. A. Trapeznikova, “Conference of the Academy of Sciences of the USSR on the Peaceful Uses of Atomic Energy,” USAEC Report AEC-tr-2435, Part 1, Moscow, 1956, pp. 239-250.
- H. Y. Goksu, E. Bulur and W. Wahl, “Beta Dosimetry Using Thin-Layer α-Al2O3:C TL Detectors,” Radiation Protection Dosimetry, Vol. 84, No. 1-4, 1999, pp. 451- 455.
- O. Roy, “Etude de la Luminescence Stimulée Optiquement (OSL) pour la Détection des Rayonnements: Application à un Capteur à Fibre Optique de Rayonnement γ,” CEA Direction de l’Information Scientifique et Technique, 1998.
- R. Chen, “Advantages and Disadvantages in the Utilisa- tion of Thermoluminescence (Tl) and Optically Stimu- lated Luminescence (OSL) for Radiation Dosimetry,” IRPA Regional Congress on Radiation Protection in Central Europe, Dubrovnik, Croatia, 20-25 May 2001, pp. 1-8.
- S. W. McKeever and M. Moscovitch, “Topics under Debate—On the Advantages and Disadvantages of Optically Stimulated Luminescence Dosimetry and Thermolumine- scence Dosimetry,” Radiation Protection Dosimetry, Vol. 104, No. 3, 2003, pp. 263-270.
- N. K. Umisedo, E. M. Yoshimura, P. B. R. Gasparian, E. G. Yukihara, “Comparison between Blue and Green Sti- mulated Luminescence of Al2O3:C,” Radiation Measurements, Vol. 45, No. 2, 2010, pp. 151-156. doi:10.1016/j.radmeas.2010.02.001
- S. W. S. McKeever, M. W. Blair, E. Bulur, R. Gaza, R. Gaza, R. Kalchgruber, D. M. Klein and E. G. Yukihara, “Recent Advances in Dosimetry Using the Optically Sti- mulated Luminescence of Al2O3:C,” Radiation Protection Dosimetry, Vol. 109, 2004, No. 4, pp. 269-276.
- D. J. Huntley, D. I. Godfrey-Smith and M. L. W. Thewalt, “Optical Dating of Sediments,” Nature, Vol. 313, 1985, pp. 105-107. doi:10.1038/313105a0
- D. I. Godfrey-Smith and B. Pass, “A New Method of Retrospective Radiation Dosimetry: Optically Stimulated Luminescence in Dental Enamel,” Health Physics, Vol. 72, No. 5, 1997, pp. 744-749. doi:10.1097/00004032-199705000-00010
- J. L. Genicot, M. Moyaerts and W. Schroeyers, “Description of a Portable Devices Developed at SCK?CEN for OSL and TL Dosimetry,” Radiation Measurements, Vol. 46, No. 12, 2011, pp. 1578-1581.