Direct Analytical Method to Calculate Photopeak Efficiency and Photopeak Attenuation Coefficient of NaI(Tl) Well-Type Detector — Oak Academic Publishing
Research ArticleOpen AccessGoogle Scholar indexed
Direct Analytical Method to Calculate Photopeak Efficiency and Photopeak Attenuation Coefficient of NaI(Tl) Well-Type Detector
Physics Department, Faculty of Science, Princess Nourah Bint Abdulrahaman University, Riyadh, Saudi Arabia
,
Physics Department, Faculty of Science, Alexandria University, Alexandria, Egypt
In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from 152 Eu, 137 Cs and 60 Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.
KeywordsNaI(Tl) Well-Type Scintillation DetectorFull-Energy Peak EfficiencyPhotopeak Attenuation CoefficientGamma-Ray Point Sources
Akkurt, I., Gungolu, K. and Arda, S.S. (2014) Detection Efficiency of NaI(Tl) Detector in 511-1332 keV Energy Range. Science and Technology of Nuclear Installations, 2014, Article ID: 186798.
Mavi, B. and Akkurt, I. (2010) Natural Radioactivity and Radiation Hazards in Some Building Materials Used in Isparta, Turkey. Radiation Physics and Chemistry, 79, 933-937. http://dx.doi.org/10.1016/j.radphyschem.2010.03.019
El-Khatib, A., Badawi, M.S., Abd-Elzaher, M. and Thabet, A.A. (2012) Calculation of the Peak Efficiency for NaI(Tl) Gamma Ray Detector Using the Effective Solid Angle Method. Journal of Advanced Research in Physics, 3, Article ID: 021204.
Wang, T.K., Mar, W.Y., Ying, T.H., Liao, C.H. and Tsing, C.L. (1995) HPGe Detector Absolute-Peak-Efficiency Calibration by Using the ESOLAN Program. Applied Radiation and Isotopes, 46, 933-944. http://dx.doi.org/10.1016/0969-8043(95)00190-O
Wang, T.K., Mar, W.Y., Ying, T.H., Liao, C.H. and Tsing, C.L. (1997) HPGe Detector Efficiency Calibration for Extended Cylinder and Marinelli-Beaker Sources Using the ESOLAN Program. Applied Radiation and Isotopes, 48, 83-95. http://dx.doi.org/10.1016/S0969-8043(96)00062-0
Radu, D. and Sima, O. (2010) Simulation of Gamma-Ray Spectra for Complex Measurement Systems Using GEANT 3.21. Romanian Reports in Physics, 62, 744-749.
Kurihara, O., Kim, E., Ueda, J., Yamada, Y., Kido, H., Oguri, T., Nemoto, S., Nemoto, M. and Akashi, M. (2011) Development of Accurate Radioactivity Assessment System for Radiation Survey with Various Detectors. Progress in Nuclear Science and Technology, 1, 248. http://dx.doi.org/10.15669/pnst.1.248
Faddegon, B.A., Asai, M., Per, J., Ross, C., Sempau, J., Tinslay, J. and Salvat, F. (2008) Benchmarking of Monte Carlo Simulation of Bremsstrahlung from Thick Targets at Radiotherapy Energies. Medical Physics, 35, 4308. http://dx.doi.org/10.1118/1.2975150
Jehouani, A., Ichaoui, R. and Boulkheir, M. (2000) Study of the NaI(Tl) Efficiency by Monte Carlo Method. Applied Radiation and Isotopes, 53, 887-891. http://dx.doi.org/10.1016/S0969-8043(00)00254-2
Selim, Y.S. and Abbas, M.I. (1994) Source-Detector Geometrical Efficiency. Radiation Physics and Chemistry, 44, 1-4. http://dx.doi.org/10.1016/0969-806X(94)90093-0
Selim, Y.S. and Abbas, M.I. (1995) Direct Calculation of the Total Efficiency of Cylindrical Scintillation Detectors for Non-Axial Point Sources. Egyptian Journal of Physics, 26, 79.
Selim, Y.S., Abbas, M.I. and Fawzy, M.A. (1998) Analytical Calculation of the Efficiencies of Gamma Scintillators. Part I: Total Efficiency for Coaxial Disk Sources. Radiation Physics and Chemistry, 53, 589-592. http://dx.doi.org/10.1016/S0969-806X(97)00277-6
Abbas, M.I. and Basiouni, M.M. (1999) Direct Mathematical Calculation of the Photopeak Efficiency for Gamma Rays in Cylindrical NaI(Tl) Detectors. AIP Conference Proceedings, 495, 268-272.
Selim, Y.S. and Abbas, M.I. (2000) Analytical Calculations of Gamma Scintillators Efficiencies—II. Total Efficiency for Wide Coaxial Circular Disk Sources. Radiation Physics and Chemistry, 58, 15-19. http://dx.doi.org/10.1016/S0969-806X(99)00357-6
Abbas, M.I. (2001) Analytical Formulae for Well-Type NaI (Tl) and HPGe Detectors Efficiency Computation. Applied Radiation and Isotopes, 55, 245-252. http://dx.doi.org/10.1016/S0969-8043(01)00047-1
Abbas, M.I. (2001) HPGe Detector Photopeak Efficiency Calculation Including Self-Absorption and Coincidence Corrections for Marinelli Beaker Sources Using Compact Analytical Expressions. Applied Radiation and Isotopes, 54, 761-768. http://dx.doi.org/10.1016/S0969-8043(00)00308-0
Abbas, M.I. (2001) A Direct Mathematical Method to Calculate the Efficiencies of a Parallelepiped Detector for an Arbitrarily Positioned Point Source. Radiation Physics and Chemistry, 60, 3-9. http://dx.doi.org/10.1016/S0969-806X(00)00329-7
Abbas, M.I. and Selim, Y.S. (2002) Calculation of Relative Full-Energy Peak Efficiencies of Well-Type Detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 480, 651-657. http://dx.doi.org/10.1016/S0168-9002(01)01225-6
Abbas, M.I., Nafee, S. and Selim, Y.S. (2006) A Simple Mathematical Method to Determine the Efficiencies of Log-Conical Detectors. Radiation Physics and Chemistry, 75, 729-736. http://dx.doi.org/10.1016/j.radphyschem.2005.12.034
Abbas, M.I. (2007) Direct Mathematical Method for Calculating Full-Energy Peak Efficiency and Coincidence Corrections of HPGe Detectors for Extended Sources. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 256, 554-557. http://dx.doi.org/10.1016/j.nimb.2006.12.056
Abbas, M.I. (2010) Analytical Approach to Calculate the Efficiency of 4π NaI(Tl) Gamma-Ray Detectors for Extended Sources. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 615, 48-52. http://dx.doi.org/10.1016/j.nima.2009.12.058
Abbas, M.I. (2010) Analytical Formulae for Borehole Scintillation Detectors Efficiency Calibration. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 622, 171-175. http://dx.doi.org/10.1016/j.nima.2010.06.241
Gouda, M.M., Badawi, M.S., El-Khatib, A.M., Thabet, A.A., and Abbas, M.I. (2015) Calibration of Well-Type NaI(Tl) Detector Using a Point Sources Measured out the Detector Well at Different Axial Distances. Journal of Instrumentation, 10, P03022.