The beam energy measurement system is significant and profit for both BES-III detector and BEPC-II accelerator. The detection of the high energy scattering photons is realized by virtue of the Compton backscattering principle. Many advanced techniques and precise instruments are employed to acquire the highly accurate measurement of positron/electron beam energy. During five years’ running period, in order to satisfy the requirement of data taking and enhance the capacity of measurement itself, the upgradation of system is continued, which involves the components reformation of laser and optics subsystem, replacement of view-port of the laser to vacuum insertion subsystem, the usage of electric cooling system for high purity germanium detector, and the refinement of data acquisition and processing subsystem. The upgrading of system guarantees the smooth and effective measuring of beam energy at BEPC-II and accommodates the accurate offline energy values for further physics analysis at BES-III.
KeywordsLaserHPGe DetectorBeam Energy Measurement
Wang, J.Q., et al. (2010) Status and Performance of BEPCII. Proceedings of International Particle Accelerator Conference (IPAC’10), Kyoto, 23-28 May 2010, 2359-2361.
Preliminary Design Report of Accelerator BEPC (2003) Second Version. (In Chinese) http://acc-center.ihep.ac.cn/bepcii/bepcii.htm
Ablikim, M., et al. (2010) Design and Construction of the BESIII Detector. Nuclear Instruments and Methods in Physics Research, 614, 345-399. http://dx.doi.org/10.1016/j.nima.2009.12.050
Chao, K.-T. and Wang, Y.-F. (2009) Physics at BESIII. International Journal of Modern Physics A (Suppl. Issue 1), 24, iii-xix. http://www.worldscientific.com/doi/pdf/10.1142/S0217751X09046 400
Fu, C.-D. and Mo, X.-H. (2008) Significance of Absolute Energy Scale for Physics at BESIII. Chinese Physics C, 32, 776-780. http://dx.doi.org/10.1088/1674-1137/32/10/002
Mo, X.-H. (2007) Study of High Precision τ Mass Measurement at BESIII. Nuclear Physics B—Proceedings Supplements, 169, 132-139. http://dx.doi.org/10.1016/j.nuclphysbps.2007.02.107
Wang, Y.-K., Mo, X.-H., Yuan, C.-Z. and Liu, J.P. (2007) Optimization of the Data Taking Strategy for a High Precision τ Mass Measurement. Nuclear Instruments and Methods in Physics Research, 583, 479-484. http://dx.doi.org/10.1016/j.nima.2007.09.026
Achasov, M.N., et al. (2009) Energy Determination at BEPC-II. Nuclear Physics B—Pro-ceedings Supplements, 189, 366-370. http://dx.doi.org/10.1016/j.nuclphysbps.2009.03.059
Mo, X.-H., et al. (2010) Beam Energy Measurement System at BEPC II. Chinese Physics C, 34, 912-917. http://dx.doi.org/10.1088/1674-1137/34/6/050
Abakumova, E.V., et al. (2011) The Beam Energy Measurement System for the Beijing Electron-Positron Collider. Nuclear Instruments and Methods in Physics Research Section A, 659, 21-29. http://dx.doi.org/10.1016/j.nima.2011.08.050
Zhang, J.Y., et al. (2012) The Beam Energy Measurement System for the Beijing Electron-Positron Collider. Nuclear Physics B—Proceedings Supplements, 225-227, 309-314. http://dx.doi.org/10.1016/j.nuclphysbps.2012.02.064
Ablikim, M., et al. (2014) Precision Measurement of the Mass of the τ Lepton. Physical Review D, 90, Article ID: 012001.
Mo, X.-H., et al. (2008) Working principles of the energy measurement system at BEPCII. Chinese Physics C, 32, 995-1002. http://dx.doi.org/10.1088/1674-1137/32/12/011
Patel, C.K.N. (1964) Continuous-Wave Laser Action on Vibrational-Rotational Transitions of CO2. Physical Review, 136, 1187-1193. http://dx.doi.org/10.1103/PhysRev.136.A1187
Abakumova, E.V., Achasov, M.N., Krasnov, A.A., et al. (2015) The System for Delivery of IR Laser Radiaton into High Vacuum. Journal of Instrumentation, 10, Article ID: T09001. http://dx.doi.org/10.1088/1748-0221/10/09/T09001
Abakumova, E., et al. (2012) Vacuum Chamber for the Measurement System of the Beam Energy. Physics Procedia, 32, 753-756. http://dx.doi.org/10.1016/j.phpro.2012.03.630
Achasova, M.N. and Yu, N. Muchnoia. arXiv:1404.2094v1
Knoll, G.F. (1979) Radiaiton of Detectrion and Measurement. John Wiley & Sons, New York.
User’s Manual. X-Cooler II Mechanical Cooler for HPGe Detector, ORTEC.
Gin, D., et al. ITER High Resolution Gamma Spectrometry. ITR/P5-39. http://www-naweb.iaea.org/napc/physics/FEC/FEC2012/papers/42 3_ITRP539.pdf
Zhang, J., Cai, X. and Mo, X. (2013) On Two Cryogenic Systems of High Purity Germanium Detector. Detection, 1, 13-20. http://dx.doi.org/10.4236/detection.2013.12003
Grigorescu, E.L., et al. (2002) Standardization of 152Eu. Applied Radiation and Isotopes, 56, 435-439. http://dx.doi.org/10.1016/S0969-8043(01)00227-5
Yang, Q.L., et al. (2012) Preparation of Standard Radioactive Solution of 152Eu. Journal of Nuclear and Radiochemistry, 34, 223-228.
Mo, X.-H., Zhang, J.-Y., Zhang, Q.-J., et al. (2011) Study of Radiation Background at the North Crossing Point of the BEPC II in Collision Mode. Chinese Physics C, 35, 642-655. http://dx.doi.org/10.1088/1674-1137/35/7/009
Mo, X.-H., Zhang, J.-Y. and Zhang, T.-B. (2009) Measurement of Radiation Dose at the North Interaction Point of BEPC II. Chinese Physics C, 33, 914-921. http://dx.doi.org/10.1088/1674-1137/33/10/017
Achasov, M.N., et al. (2008) BINPP Reprint 2008-4. ArXiv:0804.0159
Mo, X. (2014) Uncertainty of the Beam Energy Measurement in the e + e - Collision Using Compton Backscattering. Chinese Physics C, 38, Article ID: 106203. http://dx.doi.org/10.1088/1674-1137/38/10/106203
Alkemade, P.F.A., Alderliesten, C., De Wit, P. and Van der Leun, C. (1982) The Energy of the 6.13 MEV γ-Transition in 16O Related to the Gold Standard. Nuclear Instruments and Methods in Physics Research, 197, 383-390. http://dx.doi.org/10.1016/0167-5087(82)90332-5
Kessler Jr., E.G., Dewey, M.S., Deslattes, R.D., Henins, A., Borner, H.G., Jentschel, M., Doll, C. and Lehmann, H. (1999) The Deuteron Binding Energy and the Neutron Mass. Physics Letters A, 255, 221-229. http://dx.doi.org/10.1016/S0375-9601(99)00078-X
Database of Prompt Gamma Rays from Slow Neutron Capture for Elemental Analysis (2007) STI/PUB/1263. 251 p.
Abakumova, E.V., Achasov, M.N., Berkaeva, D.E., et al. (2014) A System of Beam Energy Measurement Based on the Compton Backscattered Laser Photons for the VEPP-2000 Electron-Positron Collider. Nuclear Instruments and Methods in Physics Research, 774, 35-40. http://dx.doi.org/10.1016/j.nima.2014.01.020