Diagnostic Reference Level in Frontal Chest X-Ray in Western Côte d’Ivoire
- 1 Laboratory of Nuclear Physics and Radiation Protection, Training and Research Unit, Sciences of Matter and Technology, Félix Houphouet-Boigny University, Abidjan, Côte d’Ivoire
- 2 Radiation Protection and Nuclear Security Authority, Abidjan, Côte d’Ivoire
- 3 Radiation Protection and Nuclear Security Authority, Abidjan, Côte d’Ivoire
- 4 High Normal School, Abidjan, Côte d’Ivoire
- 5 High Normal School, Abidjan, Côte d’Ivoire
- 6 High Normal School, Abidjan, Côte d’Ivoire
Abstract
Our study aims to determine diagnostic reference levels (DRL) for chest front examination in postero anterior (PA) for optimizing patient entrance surface dose (ESD) and dose-area product (DAP) of patients in west of C ô te d’Ivoire. 90 patients from three hospitals undergoing conventional radiology were considered. The ESD and DAP for each patient were obtained during chest radiography (PA) examination. The measurements were performed with the device call Dose-Area Product-meter (DAP-meter) with brand Diamentor M4-KDK, type 11017. The DRL were obtained in applying the 75th percentile statistical method to the obtained ESD and DAP. The obtained DRL in ESD for chest radiography for all rooms is 0.40 mGy and in DAP is 54.85 cGy · cm 2 . Our DRL for ESD is higher than those obtained in Abidjan District and in other countries like UK and Cameroon. Our DRL for DAP is higher than those from Abidjan and all other countries for which a similar study was made. The comparison of these values to those from Abidjan and other countries, shows us that radiology technicians can make efforts to choose radiological parameters to reduce ESD. They must use convenable the X-rays tube to reduce DAP by reducing the patient exposure surface.
- IRSN PRP-HOM (2014) Analyse des données relatives à la mise à jour des niveaux de référence diagnostiques en radiologie et en médecine nucléaire. Bilan 2011-2012. Rapport parut en 2014.
- Autorité de Sûreté Nucléaire (ASN) France (2013) Recueil de textes réglementaires relatifs à la radioprotection. Publié le 22/08/2013.
- Konaté, I., Monnehan, G., Gogon, D., Koua, A. and Dali, T. (2017) Détermination des Niveaux de Référence Diagnostiques en radiologie thoracique à Abidjan. Journal Africain d’Imagerie Médicale, 9, 1-6.
- Konaté, I., Monnehan, G., Gogon, D., Kezo, C., Dali, T., Koua, A. and Koudou, D. (2017) Diagnostic Reference Level in Lumbar Radiography in Abidjan, Côte d’Ivoire. The International Journal of Engineering and Science, 6, 31-35. https://doi.org/10.9790/1813-0602023135
- Monnehan, G., Anouan, K., Onoma, D., Yao, K., Kouadio, L., Koua, A. and Dali, T. (2009) Détermination des Niveaux de Référence Diagnostiques en Côte d’Ivoire: Cas de la radiographie du thorax de face et de l’abdomen sans preparation (ASP) de face chez l’adulte dans le district d’Abidjan et dans la region du sud comoé. Revue Internationale des Sciences et Technologie, 14, 45-53.
- Journal Officiel (1967) Article 4D 497 du Décret n 67-321 du 21 juillet 1967, portant codification des dispositions règlementaires prises pour application du titre VI “hygiène et sécurité service medical” de la loi n 64-290 du 1er Aout 1964, portant code du travail 9 juillet 1968, Côte d’Ivoire.
- Institut de Radioprotection et de Sûreté Nucléaire (IRSN) (2016) Analyse des données relatives à la mise à jour des niveaux de référence diagnostiques en radiologie et en nucléaire. Bilan 2013-2015. Rapport de mission 2016.
- PTW. User manual diasoft (2014) Version 5.2. D154.131.O/7. Manuel d’instructions 2014.
- Leclet, H. (2016) La métrologie des niveaux de dose dans les pratiques radiodiagnostiques. http://www.bivi.metrologie.afnor.org
- Glossaire-Statistica, Centile (2016). http://www.statsoft.fr/concepts6statistiques/glossaire/C/centile
- Mazerolle. Moyenne arithmétique (2012) Notes de cours.
- Asadinezhad, M. and Toosi, M. (2008) Doses to Patients in Some Routine Diagnostic X-Ray Examinations in Iran/Proposed the First Iranian Diagnostic Reference Levels. Radiation Protection Dosimetry, 132, 409-414. https://doi.org/10.1093/rpd/ncn308